CHAPTER 5
Maintenance and Troubleshooting
The SHOWGUN fixture uses a proprietary 2000 watt short arc metal halide lamp with a fast fit base.
Equipment surfaces may reach temperatures up to 150° C (302° F). Allow the fixture to cool before handling.
To change the lamp:
1.Loosen the two captive screws open the lamp panel to access the base of the lamp.
2.Rotate the lamp base to align with the slots in the housing and pull out of the fixture.
Replace with a PHILIPS MSR Gold SA/SE only (HES part # 55030084)
3.Use the three Phillips head screws for lamp optimization.