CHAPTER 4

Fixture Programming

RGB Color

The LED Tracking System uses Red, Green and Blue LEDs (RGB) to produce a color spectrum you can control and dim independently from the main output beam. There are 36 RGB LED modules that make up the LED Tracking System. Each RGB Module consists of a homogenizing lens and an RGB die.

LED Tracking System

The LED Tracking System uses 3 watt LEDs that can produce close to 5000 lumens of light and can be used along with or independent from the main output.The LED Tracking System allows you to select an LED color that matches the color from the main output beam or tracks with a complementary color.

LED Tracking Functions

The LED Tracking System is capable of strobing and other effects independent from those applied to the main output beam.

Color Function

Description

 

 

Continuous

Allows exact intensity control of each LED color.

 

 

Random

Selects whole colors at variable speeds.

 

 

Cycle

Cycles through colors.

 

 

Periodic Strobe

Strobes LEDs at specified intervals.

 

 

LED Tracking System Dimming

Most automated luminaires have a single intensity system. In addition to the main output intensity, the SHOWGUN provides an additional intensity system for the LED Tracking System. It operates in two modes.

Dim Tracking Mode

In this mode, the LED Tracking System dims as the main output dims. When the Output Dim channel is set at a lower intensity, it will override the LED Tracking Dim channel. Visually, the lowest level takes precedence. This ensures that both intensity systems black out when the main output blacks out (for example, when using the console’s Grand Master)

NOTE: You can view LEDs alone in the tracking mode if you close the lamp shutter.

Tracking System Independent Dim Mode

In this mode, the Dim parameter operates independently from the LED Tracking Dim Parameter, allowing separate control over output dimming and LED dimming.

NOTE: This mode may result in SHOWGUN fixtures outputting LED intensity when the console Grand Master is at zero.

32

SHOWGUN® User Manual

Image 44
Contents High End Systems, Inc , All Rights Reserved Contacting High End Systems AmericasDeclaration of Conformity According to ISO/IEC Guide 22 and EN45104Important Safety Information Product Modification WarningFCC Information Safety Symbols Injury and/or damage to equipmentWarranty Information Limited WarrantyReturning an Item Under Warranty for Repair FreightVii Viii Table of Contents Showgun Menu System Fixture Programming Maintenance and Troubleshooting Fixture Showgun FeaturesChapter Product Overview Operation ConstructionRelated Products and Accessories Part Description Part NumberSpecifications MechanicalPower OperationalEnvironmental ElectricalLithoPattern Specifications Lamp SpecificationsCable and Connector Specifications Unpacking the Fixture Chapter Setup and ConfigurationInstalling a Power Cord Cap Vatic Fitter Heads Information Danmark Installing a Line Cord Cap U.K. OnlyMounting the Fixture Mounting the Fixture Upright Truss MountingCable Connectors Linking Showgun FixturesFixture Homing Powering On the FixtureConnecting to the Link Setting the DMX Start Channel Shutting Down the FixtureShowgun Display Chapter Showgun Menu SystemNavigating the Menu System Display in Menu Locked Mode Error Message DisplayNavigational Basics Fixture Software Version DMX Start ChannelUnlocking the Menu System Exiting the Menu SystemLevel Option/Setting Description/Notes Menu MapLevel Following sensorsSetting DMX Start Channel Menu System OptionsDMX Address Menu Determining DMX Start Channel AssignmentType Used per Channel Link Fixture FixtureChannel Location Fixture Channels Start Pan/Tilt Swap Factory Default SettingsSet Parameters Menu Pan Invert Tilt InvertData Loss Timeout Lamp Life LimitFixture Mode Menu Test Options MenuCrossloading Fixture Software Homing the FixtureCopying the Boot Code Display Test Motor SetupEncoder Disable Code Menu Lamp StateInformation Menu Sensor Status MenuUnique Number DMX Values MenuTemperatures Menu Fixture HoursFixture Hours Reset Lamp HR/Strike ResetLamp Hours Lamp StrikesNext DMX Channel Display ErrorsModule Version Chapter Fixture Programming DMX Programming OverviewFull Speed verses MSpeed Control DMX Programming OptionsChannel Function Showgun DMX ParametersPan and Tilt Color Mixing CMY ColorTri Color Color Function DescriptionLED Tracking System RGB ColorLED Tracking Functions LED Tracking System DimmingShutter and Lamp Effects Shutter/Lamp Function Shutter ChannelMacros Zoom and FocusMSpeed Motor Speed Control Settings Control Setting DescriptionChapter Chapter Maintenance and Troubleshooting Fixture Component ReplacementFuse Fuse Location and Access Symptom of Failure Replacing FusesFuse Fuse Type and Rating Manufacturer HES Part Number Replacement FusesReplacing the Lamp Chapter Phase Boards Driver BoardsPhase Board Pan BoardReplacing Lithopatterns Achromatic Lens Cleaning the Showgun FixtureMicrofresnel Lens Reflector FilterAccessing the Bulk Heads Production HomingIris and Gobo Bulk Head Soft Edge Flag Bulk HeadConnect dimmer flag motors directly to 2-phase driver Flag Calibration ExampleAdjustment Calibrate the flagsChapter Power Board Connection Functions Supply Powered TroubleshootingPower Supply State Problem? Description Board LED StatesAppendix a MSpeed Conversion Table Dec Appendix B Important Safety Information Appendix B Important Safety Information Appendice C Importantes Informations Sur La Sécurité Anhang C Wichtige Hinweise Für Ihre Sicherheit Warnung Zum Schutz Vor BrandgefahrWarnung Zum Schutz Gegen Gefährliche Körperströme Warnung Zum Schutz Vor VerletzungenApéndice C Información Importante De Seguridad Advertencia Para Protección Continua Contra IncendiosAppendice C Importanti Informazioni Di Sicurezza Avvertenza Per Prevenire IncendiAvvertenza Per Prevenire Le Scosse Elettriche Avvertenza Per Non Ferire Ad Altre PersoneVigtig Sikkerhedsinformation Appendix B Important Safety Information