CHAPTER 3

SHOWGUN® Menu System

Menu Map

Level 1

Level 2

Option/Setting

Description/Notes

DMX ADDRESS

SET DMX START

1-483

Selected value becomes the first DMX value

in the range for that fixture on a DMX 512

MENU

CHANNEL: ###

 

link.

 

 

 

 

 

 

 

 

FACTORY DEFAULT

ON

Reverts fixture to default setting

 

SETTINGS: ###

OFF

Indicates a factory default has changed

 

 

 

 

 

PAN/TILT SWAP:

DISABLED

Restores default Pan and Tilt Motion

 

 

 

 

ENABLED

Swaps the Pan and Tilt Motion

 

 

 

 

 

 

 

PAN INVERT:

DISABLED

Restores default Pan motor direction

 

 

 

 

ENABLED

Inverts Pan motor direction

 

 

 

 

 

 

 

TILT INVERT:

DISABLED

Restores default Tilt motor direction

SET MENU

 

 

ENABLED

Inverts Tilt motor direction

 

 

 

 

 

 

DISPLAY LEVEL:

OFF

Display fully dimmed when menu is locked

 

 

 

 

ON

Turns display on

 

 

 

 

 

 

 

 

DISABLED

Disables lamp life tracking

 

LAMP LIFE LIMIT:

 

 

 

ENABLED

Tracks the time the lamp is on and sends a

 

 

warning at 500hrs

 

 

 

 

 

 

 

 

DATA LOSS

SHORT

Shutter closes 1 second after data loss

 

TIMEOUT:

LONG

Shutter closes when fixture shuts down

 

 

 

 

FIXTURE MODE

CROSSLOAD

NO

Safe setting

 

 

 

Uploads fixture software to all other

MENU

FIRMWARE:

YES

SHOWGUN fixtures on the link

 

 

 

 

 

 

 

 

HOME FIXTURE:

ALL

Homes all fixture functions

 

 

 

 

 

LAMP STATE:

OFF

Indicates or turns lamp off

 

 

 

 

ON

Indicates or turns lamp on

 

 

 

 

 

 

 

COPY BOOT:

NO

Does nothing when selected

 

 

 

 

YES

Copies boot code to fixture

 

 

 

 

 

 

 

DISPLAY TEST

OFF

Default Safe setting

 

 

 

TEST MENU

ON

Performs Display test

 

 

 

 

SETUP MOTORS

OFF

Default Safe setting

 

 

 

 

 

ON

Runs motor setup routine

 

 

 

 

 

 

 

ENCODER TEST

OFF

Leaves encoders enabled

 

 

 

 

ON

Disables encoders

 

 

 

 

 

 

 

CAL RGB LEDS

OFF

Default Safe setting

 

 

 

 

 

 

ON

Calibrates the RGB LEDs

 

 

 

 

 

CODE MENU

 

For factory use only

 

 

 

 

 

SENSOR STATUS

PAN

Displays absolute position of Pan

INFOMATION

MENU

TILT

Displays absolute position of Tilt

MENU

 

 

 

UNIQUE NUMBER

 

Displays fixture’s unique 10-character

 

##########

 

number

 

 

 

 

16

SHOWGUN® User Manual

Image 28
Contents High End Systems, Inc , All Rights Reserved Contacting High End Systems AmericasDeclaration of Conformity According to ISO/IEC Guide 22 and EN45104Important Safety Information Product Modification WarningFCC Information Safety Symbols Injury and/or damage to equipmentWarranty Information Limited WarrantyReturning an Item Under Warranty for Repair FreightVii Viii Table of Contents Showgun Menu System Fixture Programming Maintenance and Troubleshooting Chapter Product Overview Showgun FeaturesFixture Operation ConstructionRelated Products and Accessories Part Description Part NumberSpecifications MechanicalPower OperationalEnvironmental ElectricalCable and Connector Specifications Lamp SpecificationsLithoPattern Specifications Installing a Power Cord Cap Chapter Setup and ConfigurationUnpacking the Fixture Mounting the Fixture Installing a Line Cord Cap U.K. OnlyVatic Fitter Heads Information Danmark Mounting the Fixture Upright Truss MountingCable Connectors Linking Showgun FixturesConnecting to the Link Powering On the FixtureFixture Homing Setting the DMX Start Channel Shutting Down the FixtureNavigating the Menu System Chapter Showgun Menu SystemShowgun Display Display in Menu Locked Mode Error Message DisplayNavigational Basics Fixture Software Version DMX Start ChannelUnlocking the Menu System Exiting the Menu SystemLevel Option/Setting Description/Notes Menu MapLevel Following sensorsSetting DMX Start Channel Menu System OptionsDMX Address Menu Determining DMX Start Channel AssignmentChannel Location Fixture Channels Start FixtureType Used per Channel Link Fixture Set Parameters Menu Factory Default SettingsPan/Tilt Swap Pan Invert Tilt InvertData Loss Timeout Lamp Life LimitFixture Mode Menu Test Options MenuCrossloading Fixture Software Homing the FixtureCopying the Boot Code Display Test Motor SetupEncoder Disable Code Menu Lamp StateInformation Menu Sensor Status MenuUnique Number DMX Values MenuTemperatures Menu Fixture HoursFixture Hours Reset Lamp HR/Strike ResetLamp Hours Lamp StrikesModule Version Display ErrorsNext DMX Channel Chapter Fixture Programming DMX Programming OverviewFull Speed verses MSpeed Control DMX Programming OptionsPan and Tilt Showgun DMX ParametersChannel Function Color Mixing CMY ColorTri Color Color Function DescriptionLED Tracking System RGB ColorLED Tracking Functions LED Tracking System DimmingShutter and Lamp Effects Shutter/Lamp Function Shutter ChannelMSpeed Motor Speed Zoom and FocusMacros Control Settings Control Setting DescriptionChapter Chapter Maintenance and Troubleshooting Fixture Component ReplacementFuse Fuse Location and Access Symptom of Failure Replacing FusesReplacing the Lamp Replacement FusesFuse Fuse Type and Rating Manufacturer HES Part Number Chapter Phase Boards Driver BoardsPhase Board Pan BoardReplacing Lithopatterns Microfresnel Lens Cleaning the Showgun FixtureAchromatic Lens Reflector FilterAccessing the Bulk Heads Production HomingIris and Gobo Bulk Head Soft Edge Flag Bulk HeadConnect dimmer flag motors directly to 2-phase driver Flag Calibration ExampleAdjustment Calibrate the flagsChapter Power Supply TroubleshootingPower Board Connection Functions Supply Powered State Problem? Description Board LED StatesAppendix a MSpeed Conversion Table Dec Appendix B Important Safety Information Appendix B Important Safety Information Appendice C Importantes Informations Sur La Sécurité Anhang C Wichtige Hinweise Für Ihre Sicherheit Warnung Zum Schutz Vor BrandgefahrWarnung Zum Schutz Gegen Gefährliche Körperströme Warnung Zum Schutz Vor VerletzungenApéndice C Información Importante De Seguridad Advertencia Para Protección Continua Contra IncendiosAppendice C Importanti Informazioni Di Sicurezza Avvertenza Per Prevenire IncendiAvvertenza Per Prevenire Le Scosse Elettriche Avvertenza Per Non Ferire Ad Altre PersoneVigtig Sikkerhedsinformation Appendix B Important Safety Information