CHAPTER 3

SHOWGUN® Menu System

Fixture Hours Reset

Use this option to reset the fixture operation time to Zero.

To access the FIXTURE HOURS RESET option:

1.Press the Menu button to unlock the menu system or to move back up the system to the top level menus.

2.Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select.

3.Use the left and right arrows on the Center button to scroll to the FIXTURE HOURS RESET option and press the Enter button to select.

4.Use the up and down arrows on the Center button to scroll to YES. Press and hold the Enter button down for 5 seconds to select.

Lamp Hours

Use this option to view the lamp operation time in hours and minutes.

Lamp Strikes

Use this option to view the total number of lamp strikes.

Lamp HR/Strike Reset

After installing a new lamp the Lamp hours and Lamp strike sensors must be reset to 0 before the Lamp will strike.

To access the LAMP HR/STRIKE RESET option:

1.Press the Menu button to unlock the menu system or to move back up the system to the top level menus.

2.Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select.

3.Use the left and right arrows on the Center button to scroll to the LAMP HR/STRIKE RESET option and press the Enter button to select.

4.Use the up and down arrows on the Center button to scroll to YES. Press and hold the Enter button down for 5 seconds to select.

Lamp Status

This option displays the current Lamp Status as LAMP OFF, LAMP ON, LAMP STRIKING, or LAMP ERROR.

Software Version

This option display’s the fixture’s CPU board Software version. The version number is composed of: V(Major).(Minor).(Build).

SHOWGUN® User Manual

27

Image 39
Contents High End Systems, Inc , All Rights Reserved Americas Contacting High End SystemsAccording to ISO/IEC Guide 22 and EN45104 Declaration of ConformityProduct Modification Warning Important Safety InformationInjury and/or damage to equipment FCC Information Safety SymbolsFreight Warranty InformationLimited Warranty Returning an Item Under Warranty for RepairVii Viii Table of Contents Showgun Menu System Fixture Programming Maintenance and Troubleshooting Showgun Features Chapter Product OverviewFixture Construction OperationPart Description Part Number Related Products and AccessoriesMechanical SpecificationsElectrical PowerOperational EnvironmentalLamp Specifications Cable and Connector SpecificationsLithoPattern Specifications Chapter Setup and Configuration Installing a Power Cord CapUnpacking the Fixture Installing a Line Cord Cap U.K. Only Mounting the FixtureVatic Fitter Heads Information Danmark Truss Mounting Mounting the Fixture UprightLinking Showgun Fixtures Cable ConnectorsPowering On the Fixture Connecting to the LinkFixture Homing Shutting Down the Fixture Setting the DMX Start ChannelChapter Showgun Menu System Navigating the Menu SystemShowgun Display Fixture Software Version DMX Start Channel Display in Menu Locked ModeError Message Display Navigational BasicsExiting the Menu System Unlocking the Menu SystemMenu Map Level Option/Setting Description/NotesFollowing sensors LevelDetermining DMX Start Channel Assignment Setting DMX Start ChannelMenu System Options DMX Address MenuFixture Channel Location Fixture Channels StartType Used per Channel Link Fixture Factory Default Settings Set Parameters MenuPan/Tilt Swap Tilt Invert Pan InvertLamp Life Limit Data Loss TimeoutHoming the Fixture Fixture Mode MenuTest Options Menu Crossloading Fixture SoftwareLamp State Copying the Boot CodeDisplay Test Motor Setup Encoder Disable Code MenuDMX Values Menu Information MenuSensor Status Menu Unique NumberFixture Hours Temperatures MenuLamp Strikes Fixture Hours ResetLamp HR/Strike Reset Lamp HoursDisplay Errors Module VersionNext DMX Channel DMX Programming Options Chapter Fixture ProgrammingDMX Programming Overview Full Speed verses MSpeed ControlShowgun DMX Parameters Pan and TiltChannel Function Color Function Description Color MixingCMY Color Tri ColorLED Tracking System Dimming LED Tracking SystemRGB Color LED Tracking FunctionsShutter/Lamp Function Shutter Channel Shutter and Lamp EffectsZoom and Focus MSpeed Motor SpeedMacros Control Setting Description Control SettingsChapter Replacing Fuses Chapter Maintenance and TroubleshootingFixture Component Replacement Fuse Fuse Location and Access Symptom of FailureReplacement Fuses Replacing the LampFuse Fuse Type and Rating Manufacturer HES Part Number Chapter Driver Boards Phase BoardsPan Board Phase BoardReplacing Lithopatterns Cleaning the Showgun Fixture Microfresnel LensAchromatic Lens Filter ReflectorSoft Edge Flag Bulk Head Accessing the Bulk HeadsProduction Homing Iris and Gobo Bulk HeadFlag Calibration Example Connect dimmer flag motors directly to 2-phase driverCalibrate the flags AdjustmentChapter Troubleshooting Power SupplyPower Board Connection Functions Supply Powered Board LED States State Problem? DescriptionAppendix a MSpeed Conversion Table Dec Appendix B Important Safety Information Appendix B Important Safety Information Appendice C Importantes Informations Sur La Sécurité Warnung Zum Schutz Vor Verletzungen Anhang C Wichtige Hinweise Für Ihre SicherheitWarnung Zum Schutz Vor Brandgefahr Warnung Zum Schutz Gegen Gefährliche KörperströmeAdvertencia Para Protección Continua Contra Incendios Apéndice C Información Importante De SeguridadAvvertenza Per Non Ferire Ad Altre Persone Appendice C Importanti Informazioni Di SicurezzaAvvertenza Per Prevenire Incendi Avvertenza Per Prevenire Le Scosse ElettricheVigtig Sikkerhedsinformation Appendix B Important Safety Information