CHAPTER 1

Product Overview

Lamp Specifications

Lamp: PHILIPS MSR Gold SA/SE

Color Temperature: 6000K

Lamp Life 50%: 750 hrs

CRI: >80

CIE: X=.320; Y=.330

Cable and Connector Specifications

DMX data cables: Belden® 9841 or equivalent (meets specifications for EIA RS-485 applications) with the following characteristics:

•2-conductor twisted pair plus a shield

•maximum capacitance between conductors - 30 pF/ft. •maximum capacitance between conductor and shield - 55 pF/ft. •maximum resistance of 20Ω / 1000 ft.

•nominal impedance 100-140Ω

DMX data connectors: 5-pin male and female XLR connectors

DMX data terminators: Male XLR connector with 120 ohm terminator

LithoPattern Specifications

Diameter : 64.9 mm ± .20 mm (2.56 in ± .008 in)

Clear Aperture: 53.34 mm ± .25 mm (2.1 in ± .01 in)

Concentricity of Clear Aperture: ± .18 mm (.007 in)

Maximum Thickness: 2.80 mm (.17in)

6

SHOWGUN® User Manual

Image 18
Contents High End Systems, Inc , All Rights Reserved Contacting High End Systems AmericasDeclaration of Conformity According to ISO/IEC Guide 22 and EN45104Important Safety Information Product Modification WarningFCC Information Safety Symbols Injury and/or damage to equipmentReturning an Item Under Warranty for Repair Warranty InformationLimited Warranty FreightVii Viii Table of Contents Showgun Menu System Fixture Programming Maintenance and Troubleshooting Showgun Features Chapter Product OverviewFixture Operation ConstructionRelated Products and Accessories Part Description Part NumberSpecifications MechanicalEnvironmental PowerOperational ElectricalLamp Specifications Cable and Connector SpecificationsLithoPattern Specifications Chapter Setup and Configuration Installing a Power Cord CapUnpacking the Fixture Installing a Line Cord Cap U.K. Only Mounting the FixtureVatic Fitter Heads Information Danmark Mounting the Fixture Upright Truss MountingCable Connectors Linking Showgun FixturesPowering On the Fixture Connecting to the LinkFixture Homing Setting the DMX Start Channel Shutting Down the FixtureChapter Showgun Menu System Navigating the Menu SystemShowgun Display Navigational Basics Display in Menu Locked ModeError Message Display Fixture Software Version DMX Start ChannelUnlocking the Menu System Exiting the Menu SystemLevel Option/Setting Description/Notes Menu MapLevel Following sensorsDMX Address Menu Setting DMX Start ChannelMenu System Options Determining DMX Start Channel AssignmentFixture Channel Location Fixture Channels StartType Used per Channel Link Fixture Factory Default Settings Set Parameters MenuPan/Tilt Swap Pan Invert Tilt InvertData Loss Timeout Lamp Life LimitCrossloading Fixture Software Fixture Mode MenuTest Options Menu Homing the FixtureEncoder Disable Code Menu Copying the Boot CodeDisplay Test Motor Setup Lamp StateUnique Number Information MenuSensor Status Menu DMX Values MenuTemperatures Menu Fixture HoursLamp Hours Fixture Hours ResetLamp HR/Strike Reset Lamp StrikesDisplay Errors Module VersionNext DMX Channel Full Speed verses MSpeed Control Chapter Fixture ProgrammingDMX Programming Overview DMX Programming OptionsShowgun DMX Parameters Pan and TiltChannel Function Tri Color Color MixingCMY Color Color Function DescriptionLED Tracking Functions LED Tracking SystemRGB Color LED Tracking System DimmingShutter and Lamp Effects Shutter/Lamp Function Shutter ChannelZoom and Focus MSpeed Motor SpeedMacros Control Settings Control Setting DescriptionChapter Fuse Fuse Location and Access Symptom of Failure Chapter Maintenance and TroubleshootingFixture Component Replacement Replacing FusesReplacement Fuses Replacing the LampFuse Fuse Type and Rating Manufacturer HES Part Number Chapter Phase Boards Driver BoardsPhase Board Pan BoardReplacing Lithopatterns Cleaning the Showgun Fixture Microfresnel LensAchromatic Lens Reflector FilterIris and Gobo Bulk Head Accessing the Bulk HeadsProduction Homing Soft Edge Flag Bulk HeadConnect dimmer flag motors directly to 2-phase driver Flag Calibration ExampleAdjustment Calibrate the flagsChapter Troubleshooting Power SupplyPower Board Connection Functions Supply Powered State Problem? Description Board LED StatesAppendix a MSpeed Conversion Table Dec Appendix B Important Safety Information Appendix B Important Safety Information Appendice C Importantes Informations Sur La Sécurité Warnung Zum Schutz Gegen Gefährliche Körperströme Anhang C Wichtige Hinweise Für Ihre SicherheitWarnung Zum Schutz Vor Brandgefahr Warnung Zum Schutz Vor VerletzungenApéndice C Información Importante De Seguridad Advertencia Para Protección Continua Contra IncendiosAvvertenza Per Prevenire Le Scosse Elettriche Appendice C Importanti Informazioni Di SicurezzaAvvertenza Per Prevenire Incendi Avvertenza Per Non Ferire Ad Altre PersoneVigtig Sikkerhedsinformation Appendix B Important Safety Information