Samsung SNC-C7478P manual User

Page 42

Setup Tool

camera using the web browser. The default port number is 80(TCP).

Device Port (TCP)

A port used to control video transmission. The default value is 60001(TCP).

TCP Streaming Port

A port used to transfer video using the TCP protocols. The default value is 60002(TCP).

UDP Streaming Port

A port used to transfer video using the UDP protocols. The default value is 60003(UDP).

Upload Port(TCP)

A port used to upgrade software. Default value is 60004(TCP).

IPv6 Enable

IPv4 and IPv6 may be enabled simultaneously. When IPv6 is enabled, your camera will receive an IP address according to the configuration in the network router.

Multicast Address

Shows IP address set for video transmission using UDP Multicast.

The default value is 225.128.1.128. It is recommended to set it to between 224.0.0.0 and 239.255.255.255.

Multicast Port

Shows UDP port set for video transmission using UDP Multicast. The default value is 60005(UDP).

TTL

TTL stands for “Time To Live” that allows you to set the number of routers so that the packet can pass through. Each router decreases the TTL value one by one when a packet passes it through. If the TTL value reaches 0, the packet cannot pass through a router. The default value is 63. It is recommended to set it to between 0 and 255.

RTSP Port

Set up the RTSP port number to use. The default value is 554.

RTP Port Range

Set up the range of port number to use for RTP Protocol.

The Start number of RTP Port has to be even number and the last number must be greater than the start number +4. I.e. the difference should be at least 4.

RTP Multicast Address

Set up IP Address for RTP/UDP Multicast.

RTP Multicast Port

Set up Port number used in RTP/UDP Multicast. It is noted that RTP Multicast Port must be a even number.

RTP Multicast TTL

Set up TTL for RTP/UDP Multicast. TTL is a number between 0 ~ 255.

USER

Login Authentication

You can determine whether to require login authentication for users.

If it is set to <Enable>, the users can connect to the system through login authentication, while it is set to <Disable>, the users can connect to the system without login authentication. However, users connected to the system without login have USER permission.

When the setting is complete, click the [Apply] button.

User Login ID/Password List

Shows user ID, password and level (permissions) in a list.

You can register up to 10 users. The default administrator ID is root. <Administrator> cannot be deleted or added and you can change the password only.

M For the ID and password, up to 9 alphanumeric and some special characters are allowed.

You cannot register a duplicated user ID.

You cannot register root or guest user ID.

About User Level

Administrator

The Administrator can use all

 

functions and change the ptz control,

 

setup or search.

 

 

Operator

The Operator can use all function

 

except setup and search functions.

 

 

User

The User can monitor video only.

 

 

42 – 36x IP Smart Dome Camera

Image 42
Contents 36x IP Smart Dome Camera Safety information FCC Statement Important Safety Instructions Contents Specifications Network SetupSetup Tool Web ViewerFeatures IntroductionRecommended PC Specifications Compatible IP RoutersLinksys Netgear Housing Body Product & AccessoriesAccessories ProductDome Cover RJ-45 Ethernet port, Alarm Input/outputParts Name & Functions Network BoxCommunication Protocol Setup InstallationDIP Switch Setup Camera ID SetupInstallation Using pole Mount BracketRS-485 Termination Resistor Plug the connector of cable from network box into properly Cabling Audio Input/Ouput Connection Alarm Input ConnectionVideo Connection Connect with BNC coaxial cableOperation Auto CalibrationPattern PresetAuto Pan Delete Auto Pan To delete Auto Pan, use OSD menuScan ScheduleOther Functions Semi Auto Focus OSD Display of Main ScreenGeneral Rules of Key Operation for Menu UndefinedPrivacy Zone Mask Setup How to use OSD MenuDisplay Setup Main MenuMotion Setup Privacy Zone Area SetupPrivacy Zone Size Adjustment Function Setup Parking Action SetupHOME/PRESET/PATTERN/AUTOPAN/SCAN Edit Preset Label Preset SetupEdit Preset Scene CANCEL/OKAuto Pan Setup Pattern SetupBack Space Char Scan Setup Edit PatternEdit Scan Action no NONE/PRESET/AUTO PAN/PATTERN Set up items such as Action, NO., Dwell and OPT OPTSchedule Setup Edit ScheduleCamera Setup White Balance SetupAuto Exposure Setup System Setup PAN Axis / Tilt Axis / Zoom / DD Set North Direction You can set up North directionIt is noted that Home is not effective to Tilt angle After selecting a language, press the Near or Enter keyInitial Configuration Table System InitializeNetwork Setup Power on the IP Smart Dome using the power adapterQuick Start of Network Connection Initial Setup via a Crossover Cable IP Type Guide to Network SetupCase a Dynamic IP or PPPoE + Personal Router Most Soho IP AddressCase B StaticFixed IP + Personal Router Efficient Example  Use the assigned default gateway from your ISP Default  You may select any number between 80, 10000 ~Device portTCP Port Forwarding DynamicConnecting To The IP Smart Dome Camera Starting IP Smart Dome CameraInstalling ActiveX Logging to the IP Smart Dome CameraWeb Viewer Live ViewerSetup Tool Video & Audio ConfigurationUser DATE/TIME LanguageDigital Image Stabilizer LOGSoftware Update ResetHttps Transfer Setup FTPSmtp Alarm Image Setup Alarm Input SetupMotion To set a motion detection target areaStreaming Setup ScheduleDdns SnmpSpecifications DetailsSpecifications Dimension ˝ NTP Pipe Thread145.4 259.0 Unit mm AB82-02348A Cámara Domo Inteligente IP Información de Seguridad PrecauciónPrecaución Instrucciones importantes de seguridad Instalación Índice generalIntroducción FuncionamientoEspecificaciones Configuración RedHerramienta de Configuración HttpsIntroducción CaracterísticasCaracterísticas recomendadas del ordenador Routers IP CompatiblesAccesorios Producto Y AccesoriosProducto Carcasa de alojamientoDE Domo Nombre DE Componentes Y FuncionesMecanismo PTZ Ventilador Calentador Cubierta DE DomoConfiguración del protocolo de comunicaciones Configuración del interruptor DIPConfiguración de ID de cámara InstalaciónInstalación CON EL Soporte DE Montaje EN Poste Resistencia de terminación RS-485Pin 8 Resistencia de terminación RS-485 ActOn/DesOff Instalación Video BNC CableadoCable principal Conexión a toma de corrienteConexión de entrada de alarma Conexión de videoConexión de entrada y salida de audio Funcionamiento Patrón PredefinidoPanorámica automática LejosBuscar ProgramaciónOtras funciones Enfoque semiautomático Configuración GENERAL/ESPEC. de imagenVisualización de OSD de la pantalla principal DEF.PRED. ××× PREDEF. ×××Cómo utilizar el menú OSD Máscara DE Zona PrivadaConfiguración de movimiento Configuración del área de zona privadaAjuste del tamaño de la zona privada Configuración de Función Configuración de la acción de aparcamientoINICIO/PREDEF./PATRÓN/PAN AUT/BUSCAR Configuración de Predefinido Editar escena de predef CANCELAR/OKEditar etiq. predef Configuración de patrón Conf. de AutopanCarácter de retroceso Carácter de espacio Editar búsqueda Configuración de búsquedaEditar patrón Editar búsqueda Inicia la edición de la búsquedaNINGUNO/PREDEF/PAN AUTOM./PATRÓN  Configure elementos como Acción, NO., ESP. y OPCNº de acción ESPProgramación Editar programaciónConfiguración de la Cámara Conf. balance blancoConf. exposic. aut Configuración del sistema GananciaAjustar dir. norte Puede configurar la dirección Norte ¿Ajustar posición de inicio?Tras seleccionar un idioma, presione Cerca o la tecla Intro Tabla de configuración inicial Inicializar SistemaFamiliarícese con la pantalla de la interfaz del visor Configuración RedInicio rápido de conexión de red Acceso a la domo inteligente IP a través de InternetConfiguración de Red Configuración inicial a través de un cable cruzadoDirección IP Guía para la configuración de redTipo de IP Máscara de subredCaso B IP estática fija + Enrutador personal Eficiente Por omisión  Puede seleccionar un número entre 80, 10000 ~ Reenvío de puertos DinámicaSi el número de puerto Http no es Inicio de la cámara Domo Inteligente IPCoNECTARSE a lA CámARA Domo Inteligente IP Conexión usando URlEl ID del administrador, root es fijo, y no puede cambiarse INSTAlAR ActivexRegistrarse en la cámara Domo Inteligente IP Visor en directo Configuración DE Video Y Audio Herramienta de Configuración UsuarioFECHA/HORA IdiomaEstabilizador Digital DE Imagen RegistroActualización DE Software ReinicioRuta de Carga Usar Modo PasivoDirección de servidor FTP PuertoMensaje Imagen de Pre/PostalarmaTítulo Modo de transferenciaConfigurar una zona final de detección de movimiento MovimientoProtocolo de flujo de datos Función de transferencia programadaIntervalo de transferencia Control de flujo de datosDdns público Ddns ConfiguraciónContraseña de usuario Nombre de hostEspecificaciones EspecificacionesEspecificaciones Hilo DE Rosca de Pipa 1.5˝NTP 145.4 259.0 Unidad mm AB82-02348A