Samsung SNC-C7478P manual Specifications

Page 51

 

 

 

 

Specifications

Specifications

 

 

 

 

 

 

 

 

Model

 

SNC-C7478

 

OS

 

Embedded Linux

 

 

 

Flash memory

32M byte

 

 

 

 

 

Network Board

Hardware

 

RAM

256M byte

 

 

 

 

 

 

DSP

TI Davinci

 

 

 

 

 

 

 

 

 

 

 

Ethernet

RJ-45 (10/100BASE-T)

 

 

 

 

 

Compression

MPEG4 / MJPEG Dual Codec

 

 

 

 

 

 

 

 

D1

720x480

Video

Resolution

 

VGA

640x480

 

 

CIF

352x240

 

 

 

 

Frame Rate

30, 15, 8, 3, 1 fps

 

 

 

 

 

Quality

1 ~ 10 level

 

 

 

 

Audio

Compression

G.711

 

 

 

 

Bi-Directional Communication

Yes

 

 

 

 

 

DIS

Digital Image Stabilizer

Yes (Network Only)

 

 

 

 

Motion Detection

Sensitivity

High, Medium, Low

 

IP

 

IPv4 / IPv6

 

 

 

 

TCP/IP, UDP/IP, RTP/RTSP, NTP, HTTP, HTTPS, SSL,

 

Network

 

IPv4

DHCP, PPPoE, FTP, SMTP, ICMP, IGMP,

 

Protocol

 

 

SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS

Protocol

 

 

 

 

 

IPv6

TCP/IP, HTTP, HTTPS, SSL, DHCP

 

 

 

 

 

 

 

 

Streaming

Unicast, Multicast

 

Security

HTTPS(SSL), Digest Authentication (ID/PW)

 

DDNS

Supporting Samsung DDNS and Public DDNS servers

 

Maximum User Access

Max 10 Users at Unicast Mode

 

Max 20 Users at Multicast Mode

 

 

 

 

 

 

 

 

 

Connection

 

 

Administrator

Live Monitoring, PTZ control, SETUP

 

User Access Level

 

Operator

Live Monitoring, PTZ control

 

 

 

User

Live Monitoring

 

 

 

 

 

 

Alarm Input

JPEG Image transfer : FTP, E-mail

 

Notification : notify to viewer Alarm Out

 

 

 

 

Event

 

 

 

 

Motion Detection

JPEG Image transfer : FTP, E-mail

 

Notification : notify to viewer Alarm Out

 

 

 

 

 

 

 

 

 

Schedule

JPEG Image transfer : FTP, E-mail

 

OS

 

Windows XP, VISTA

Client Viewer

Web browser viewer (Default)

Internet Explorer 6.0 or Higher

 

 

 

 

 

Video Player

Quicktime, VLC player (RTP/RTSP)

 

 

 

 

Language

Web Viewer UI Language

English/한국어/中國語/Français/Italiano/Español/Deutsch

Upgrade

S/W upgrade

Using Web viewer

 

 

 

 

 

 

HTTP API

 

CGI Command

Provides functionality to control cameras and set/retrieve internal parameter values.

 

 

Get JPEG image or MJPEG stream Alarm In/Out control, PTZ control

SDK

 

 

 

RTP/RTSP API

 

 

RTP Header, RTSP Command Document

 

 

 

 

 

 

 

 

 

ActiveX

 

SDK

ActiveX API for viewing data streams from network camera.

 

 

 

 

 

English – 51

Image 51
Contents 36x IP Smart Dome Camera Safety information FCC Statement Important Safety Instructions Contents Web Viewer Network SetupSetup Tool SpecificationsIntroduction FeaturesRecommended PC Specifications Compatible IP RoutersLinksys Netgear Product Product & AccessoriesAccessories Housing BodyNetwork Box RJ-45 Ethernet port, Alarm Input/outputParts Name & Functions Dome CoverCamera ID Setup InstallationDIP Switch Setup Communication Protocol SetupInstallation Using pole Mount BracketRS-485 Termination Resistor Plug the connector of cable from network box into properly Cabling Connect with BNC coaxial cable Alarm Input ConnectionVideo Connection Audio Input/Ouput ConnectionAuto Calibration OperationDelete Auto Pan To delete Auto Pan, use OSD menu PresetAuto Pan PatternScan ScheduleOther Functions Undefined OSD Display of Main ScreenGeneral Rules of Key Operation for Menu Semi Auto FocusMain Menu How to use OSD MenuDisplay Setup Privacy Zone Mask SetupMotion Setup Privacy Zone Area SetupPrivacy Zone Size Adjustment Function Setup Parking Action SetupHOME/PRESET/PATTERN/AUTOPAN/SCAN CANCEL/OK Preset SetupEdit Preset Scene Edit Preset LabelAuto Pan Setup Pattern SetupBack Space Char Scan Setup Edit PatternEdit Scan OPT NONE/PRESET/AUTO PAN/PATTERN Set up items such as Action, NO., Dwell and OPT Action noEdit Schedule Schedule SetupCamera Setup White Balance SetupAuto Exposure Setup System Setup After selecting a language, press the Near or Enter key Set North Direction You can set up North directionIt is noted that Home is not effective to Tilt angle PAN Axis / Tilt Axis / Zoom / DDSystem Initialize Initial Configuration TableNetwork Setup Power on the IP Smart Dome using the power adapterQuick Start of Network Connection Initial Setup via a Crossover Cable IP Address Guide to Network SetupCase a Dynamic IP or PPPoE + Personal Router Most Soho IP TypeCase B StaticFixed IP + Personal Router Efficient Example  Use the assigned default gateway from your ISP Default  You may select any number between 80, 10000 ~Device portTCP Dynamic Port ForwardingStarting IP Smart Dome Camera Connecting To The IP Smart Dome CameraLogging to the IP Smart Dome Camera Installing ActiveXLive Viewer Web ViewerVideo & Audio Configuration Setup ToolUser LOG LanguageDigital Image Stabilizer DATE/TIMESoftware Update ResetHttps Transfer Setup FTPSmtp Alarm Input Setup Alarm Image SetupTo set a motion detection target area Motion Schedule Streaming SetupSnmp DdnsDetails SpecificationsSpecifications Dimension ˝ NTP Pipe Thread145.4 259.0 Unit mm AB82-02348A Cámara Domo Inteligente IP Precaución Información de SeguridadPrecaución Instrucciones importantes de seguridad Funcionamiento Índice generalIntroducción InstalaciónHttps Configuración RedHerramienta de Configuración EspecificacionesCaracterísticas IntroducciónRouters IP Compatibles Características recomendadas del ordenadorCarcasa de alojamiento Producto Y AccesoriosProducto AccesoriosVentilador Calentador Cubierta DE Domo Nombre DE Componentes Y FuncionesMecanismo PTZ DE DomoInstalación Configuración del interruptor DIPConfiguración de ID de cámara Configuración del protocolo de comunicacionesInstalación CON EL Soporte DE Montaje EN Poste Resistencia de terminación RS-485Pin 8 Resistencia de terminación RS-485 ActOn/DesOff Instalación Conexión a toma de corriente CableadoCable principal Video BNCConexión de entrada de alarma Conexión de videoConexión de entrada y salida de audio Funcionamiento Lejos PredefinidoPanorámica automática PatrónBuscar ProgramaciónOtras funciones DEF.PRED. ××× PREDEF. ××× Configuración GENERAL/ESPEC. de imagenVisualización de OSD de la pantalla principal Enfoque semiautomáticoMáscara DE Zona Privada Cómo utilizar el menú OSDConfiguración de movimiento Configuración del área de zona privadaAjuste del tamaño de la zona privada Configuración de Función Configuración de la acción de aparcamientoINICIO/PREDEF./PATRÓN/PAN AUT/BUSCAR Configuración de Predefinido Editar escena de predef CANCELAR/OKEditar etiq. predef Configuración de patrón Conf. de AutopanCarácter de retroceso Carácter de espacio Editar búsqueda Inicia la edición de la búsqueda Configuración de búsquedaEditar patrón Editar búsquedaESP  Configure elementos como Acción, NO., ESP. y OPCNº de acción NINGUNO/PREDEF/PAN AUTOM./PATRÓNEditar programación ProgramaciónConfiguración de la Cámara Conf. balance blancoConf. exposic. aut Ganancia Configuración del sistemaAjustar dir. norte Puede configurar la dirección Norte ¿Ajustar posición de inicio?Tras seleccionar un idioma, presione Cerca o la tecla Intro Inicializar Sistema Tabla de configuración inicialAcceso a la domo inteligente IP a través de Internet Configuración RedInicio rápido de conexión de red Familiarícese con la pantalla de la interfaz del visorConfiguración inicial a través de un cable cruzado Configuración de RedMáscara de subred Guía para la configuración de redTipo de IP Dirección IPCaso B IP estática fija + Enrutador personal Eficiente Por omisión  Puede seleccionar un número entre 80, 10000 ~ Dinámica Reenvío de puertosConexión usando URl Inicio de la cámara Domo Inteligente IPCoNECTARSE a lA CámARA Domo Inteligente IP Si el número de puerto Http no esEl ID del administrador, root es fijo, y no puede cambiarse INSTAlAR ActivexRegistrarse en la cámara Domo Inteligente IP Visor en directo Configuración DE Video Y Audio Usuario Herramienta de ConfiguraciónRegistro IdiomaEstabilizador Digital DE Imagen FECHA/HORAReinicio Actualización DE SoftwarePuerto Usar Modo PasivoDirección de servidor FTP Ruta de CargaModo de transferencia Imagen de Pre/PostalarmaTítulo MensajeMovimiento Configurar una zona final de detección de movimientoControl de flujo de datos Función de transferencia programadaIntervalo de transferencia Protocolo de flujo de datosNombre de host Ddns ConfiguraciónContraseña de usuario Ddns públicoEspecificaciones EspecificacionesEspecificaciones Hilo DE Rosca de Pipa 1.5˝NTP 145.4 259.0 Unidad mm AB82-02348A
Related manuals