Basic operation is an operation mode that can be selected by pressing the Mode button.

Auto

In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature.

Cool

In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.

If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.

Quiet mode(,) makes the noise quieter during the operation of the indoor unit in the Cool mode.

Dry

The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air. Dry mode makes the air feel refreshing in a humid climate.

To activate the Dry mode, set temperature on the remote controller should be lower than indoor room temperature.

Fan

Fan mode can be selected to ventilate your room. Fan mode will be helpful to refresh the stale air in your room.

Heat (ARJS series)

The air conditioner heats as well as cools. Warm your room with this versatile appliance in the cold of winter.

Fan may not operate for about 3~5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up.

Quiet mode(,) makes the noise quieter during the operation of the indoor unit in the Heat mode.

Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperature is extremely low.

Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently.

English-13

ENGLISH

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 13

2014/9/26 16:38:39

Image 13
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningOperation ranges Checking before useEnglish-9 Main parts Checking the name of the partsEnglish-10 Remote controller buttons Checking the remote controllerEnglish-11 Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-14 Using the Turbo function Adjusting the air flow directionVertical air flow Horizontal air flowMode Press the button on the remote controllerEnglish-16 Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode English-17From the moment you have set the timer Using the Smart Saver functionEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on Cool/Heat modeCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterEnglish-21 Dry the Air filter in a ventilated areaEnglish-22 Bio filterBio filter sky-blue English-23 Deodorizing filterDeodorizing filter black English-24 Maintaining the air conditionerAir conditioner TroubleshootingDoes not come out English-25Press the Power button or disconnect the power plug Check if you press the Set/Cancel button on the remoteMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceEnglish-27 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-29 When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-30  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-31Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-34 Smooth the cut edges English-35Torque Cut off the remaining foam insulationCutting or extending the pipe Evacuating the indoor unitEnglish-36 Unscrew the caps at the end of each pipeCorrect Inclined English-37Cracked Wall Indoor unit Drain hose Drain hose must notEnglish-38 Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightEnglish-39 Evacuating the connected pipesEnglish-40 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mPlease fill in with indelible ink English-41 the factory refrigerant charge of the product 1975English-42 Performing the gas leak testsFixing the indoor unit in place Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-43English-44 Final Check and Trial OperationEnglish-45 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner