Cleaning the air conditioner

Make sure to turn off the power of the indoor unit and cut-off

CAUTION the power supply before cleaning the air conditioner.

Cleaning the indoor unit

Wipe the surface of the unit with a slightly wet or dry cloth when needed.

• Contact the service center when you clean the indoor unit

heat exchanger because it needs to be disassembled.

Since the panel of the indoor unit is easily scratched, you should use a micro fiber cloth to clean the panel.

When you use the micro fiber cloth, slightly dampen the cloth and remove any debris on the cloth to avoid scratches.

• Do not clean the display using alkaline detergent.

 

• Do not use sulfuric acid, hydrochloric acid, organic solvents

CAUTION

 

(such as thinner, kerosene and acetone etc.) to clean the

 

 

surface of the product or put any stickers on it.

 

They may damage the surface of the air conditioner.

Cleaning the outdoor unit heat exchanger

When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly.

Spray water to clean the dust.

• If it is difficult to clean the outdoor unit heat exchanger on

your own, contact service center.

• Be careful with the sharp edges on the CAUTION outdoor unit heat exchanger.

Heat exchanger

(Illustration may differ slightly depending on the models)

Opening the panel

Tightly grab top of the front panel and pull it down to open.

Then slightly lift the panel up.

Air filter

English-20

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 20

2014/9/26 16:38:47

Image 20
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents Safety precautions English-3For Power Supply English-4For Using English-5English-6 Do not place objects or devices under the indoor unit English-7For Cleaning English-8English-9 Checking before useOperation ranges English-10 Checking the name of the partsMain parts English-11 Checking the remote controllerRemote controller buttons Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function English-14 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction Using the Turbo functionVertical air flow Horizontal air flowPress the button on the remote controller ModeEnglish-16 Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode English-17Using the Smart Saver function From the moment you have set the timerEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cool/Heat modeCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterEnglish-21 Dry the Air filter in a ventilated areaBio filter sky-blue Bio filterEnglish-22 Deodorizing filter black Deodorizing filterEnglish-23 Maintaining the air conditioner English-24Troubleshooting Air conditionerDoes not come out English-25Check if you press the Set/Cancel button on the remote Press the Power button or disconnect the power plugMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceGeneral information English-27Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitEnglish-29 Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-30  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-31Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification English-34 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number English-35 Smooth the cut edgesTorque Cut off the remaining foam insulationEvacuating the indoor unit Cutting or extending the pipeEnglish-36 Unscrew the caps at the end of each pipeEnglish-37 Correct InclinedCracked Wall Indoor unit Drain hose Drain hose must notDrain hose installation English-38Two hoses are firmly connected, there is no water leakage Hose tightEvacuating the connected pipes English-39Adding Refrigerant English-40Outer Torque If you use a pipe longer than 5 mEnglish-41 Please fill in with indelible ink the factory refrigerant charge of the product 1975Performing the gas leak tests English-42Outdoor unit installed on the wall by rack Fixing the indoor unit in placeFixing the outdoor unit in place English-43Final Check and Trial Operation English-44How to connect your extended power cables English-45Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withTechnical Specifications English-46English-47 Questions or COMMENTS? 0211Air Conditioner