Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failure to do so may result in electric shock, fire, and explosion.

Make sure to use a socket-outlet with ground.

FOR INSTALLATION

 

CAUTION

 

Install your appliance on a level and hard floor that can support its weight.

Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the draining hose properly so that water is drained correctly.

Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste pipes as odours may arise in the future.

When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.

The water generated during the heating operation by the outdoor unit may overflow and result in property damage.

In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

FOR POWER SUPPLY

 

WARNING

 

Whenthecircuitbreakerisdamaged,contactyournearestservicecenter.

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.

This may result in electric shock or fire.

English-4

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 4

2014/9/26 16:38:36

Image 4
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents Safety precautions English-3For Power Supply English-4For Using English-5English-6 Do not place objects or devices under the indoor unit English-7For Cleaning English-8Operation ranges Checking before useEnglish-9 Main parts Checking the name of the partsEnglish-10 Remote controller buttons Checking the remote controllerEnglish-11 Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-14 Adjusting the air flow direction Using the Turbo functionVertical air flow Horizontal air flowPress the button on the remote controller ModeEnglish-16 Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode English-17Using the Smart Saver function From the moment you have set the timerEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cool/Heat modeCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterEnglish-21 Dry the Air filter in a ventilated areaEnglish-22 Bio filterBio filter sky-blue English-23 Deodorizing filterDeodorizing filter black Maintaining the air conditioner English-24Troubleshooting Air conditionerDoes not come out English-25Check if you press the Set/Cancel button on the remote Press the Power button or disconnect the power plugMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceGeneral information English-27Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-29 When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-30  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-31Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-34 English-35 Smooth the cut edgesTorque Cut off the remaining foam insulationEvacuating the indoor unit Cutting or extending the pipeEnglish-36 Unscrew the caps at the end of each pipeEnglish-37 Correct InclinedCracked Wall Indoor unit Drain hose Drain hose must notDrain hose installation English-38Two hoses are firmly connected, there is no water leakage Hose tightEvacuating the connected pipes English-39Adding Refrigerant English-40Outer Torque If you use a pipe longer than 5 mEnglish-41 Please fill in with indelible ink the factory refrigerant charge of the product 1975Performing the gas leak tests English-42Outdoor unit installed on the wall by rack Fixing the indoor unit in placeFixing the outdoor unit in place English-43Final Check and Trial Operation English-44How to connect your extended power cables English-45Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withTechnical Specifications English-46English-47 Questions or COMMENTS? 0211Air Conditioner