Samsung AR30JVFUCWKNMG manual Troubleshooting, Air conditioner, Does not come out, English-25

Page 25

Troubleshooting

Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.

PROBLEM

SOLUTION

 

 

The air conditioner

• Check power status and then operate the air conditioner

does not work at

again.

all.

• Plug in or switch on the circuit breaker and then operate

 

the air conditioner again.

 

• Ensure Isolator is switch on.

 

• Check if you have set the Off Timer. Operate the air

 

conditioner again by pressing the Power button.

The temperature

• Check if you have selected Fan/Turbo mode. In these

adjustment is not

modes,desired temperature is set to auto and you cannot

working.

adjust the temperature.

Cool/Warm air

• Check if the set temperature is higher(during Cool mode)/

does not come out

lower(during Heat mode) than the current temperature.

of the air condi-

Press the Temp + or - button on the remote controller to

tioner.

change the set temperature.

 

• Check if the Air filter is blocked by dirt. If there is a lot of

 

dust on the Air filter, cooling(heating) performance may

 

decrease. Clean them frequently.

 

• Check if the outdoor unit is covered or installed near the

 

obstacle. Take the cover off and take the obstacle away.

 

• Check if the air conditioner is operating in defrost mode.

 

When the ice formed in winter or the outdoor temperature

 

is too low, the air conditioner operates in defrost mode

 

automatically. In defrost mode, indoor fan stops and warm

 

air does not come out.

 

• If the doors or windows are open, it may cause bad cooling

 

(heating) performance. Close the doors and windows.

 

• Check if the air conditioner has just been turned on after

 

stopping cooling or heating operation. In this case, just a

 

fan will run to protect the outdoor unit compressor.

 

• Check if the pipe length is too long. When the pipe

 

length exceeds maximum allowable pipe length, cooling

 

(heating) performance may decrease.

ENGLISH

English-25

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 25

2014/9/26 16:38:50

Image 25
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningOperation ranges Checking before useEnglish-9 Main parts Checking the name of the partsEnglish-10 Remote controller buttons Checking the remote controllerEnglish-11 Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-14 Using the Turbo function Adjusting the air flow directionVertical air flow Horizontal air flowMode Press the button on the remote controllerEnglish-16 Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode English-17From the moment you have set the timer Using the Smart Saver functionEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on Cool/Heat modeCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterEnglish-21 Dry the Air filter in a ventilated areaEnglish-22 Bio filterBio filter sky-blue English-23 Deodorizing filterDeodorizing filter black English-24 Maintaining the air conditionerAir conditioner TroubleshootingDoes not come out English-25Press the Power button or disconnect the power plug Check if you press the Set/Cancel button on the remoteMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceEnglish-27 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-29 When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-30  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-31Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-34 Smooth the cut edges English-35Torque Cut off the remaining foam insulationCutting or extending the pipe Evacuating the indoor unitEnglish-36 Unscrew the caps at the end of each pipeCorrect Inclined English-37Cracked Wall Indoor unit Drain hose Drain hose must notEnglish-38 Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightEnglish-39 Evacuating the connected pipesEnglish-40 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mPlease fill in with indelible ink English-41 the factory refrigerant charge of the product 1975English-42 Performing the gas leak testsFixing the indoor unit in place Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-43English-44 Final Check and Trial OperationEnglish-45 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner
Related manuals
Manual 49 pages 24.33 Kb