Samsung AR30JVFUCWKNMG manual Fixing the installation plate, Optional accessories, English-32

Page 32

Accessories

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Plug (1)

Rubber Legs (4)

Pipe Clamps A (3)

Pipe, Ø6.35mm (1)

Ø15.88mm (1)

Insulation (1)

 

 

 

 

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Drain Hose,

Putty 100g (1)

Foam

 

Screws (6)

length 2m (1)

Insulation(1)

 

 

 

 

 

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter • Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

 

Direction of pipe

 

• Left (B)

 

 

 

• Underside_right (C)

A

 

B

• Rear_right or left (D)

 

 

D

D

C

1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

(Unit : mm)

 

67

156

364

 

 

34.5

19.5

64.5

2. Fix the indoor unit.

If you fix the indoor unit on a wall

Make sure to drill only one hole after choosing the direction of the pipe.

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

English-32

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 32

2014/9/26 16:38:54

Image 32
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents Safety precautions English-3For Power Supply English-4For Using English-5English-6 Do not place objects or devices under the indoor unit English-7For Cleaning English-8English-9 Checking before useOperation ranges English-10 Checking the name of the partsMain parts English-11 Checking the remote controllerRemote controller buttons Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function English-14 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction Using the Turbo functionVertical air flow Horizontal air flowPress the button on the remote controller ModeEnglish-16 Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode English-17Using the Smart Saver function From the moment you have set the timerEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cool/Heat modeCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterEnglish-21 Dry the Air filter in a ventilated areaBio filter sky-blue Bio filterEnglish-22 Deodorizing filter black Deodorizing filterEnglish-23 Maintaining the air conditioner English-24Troubleshooting Air conditionerDoes not come out English-25Check if you press the Set/Cancel button on the remote Press the Power button or disconnect the power plugMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceGeneral information English-27Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitEnglish-29 Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-30  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-31Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification English-34 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number English-35 Smooth the cut edgesTorque Cut off the remaining foam insulationEvacuating the indoor unit Cutting or extending the pipeEnglish-36 Unscrew the caps at the end of each pipeEnglish-37 Correct InclinedCracked Wall Indoor unit Drain hose Drain hose must notDrain hose installation English-38Two hoses are firmly connected, there is no water leakage Hose tightEvacuating the connected pipes English-39Adding Refrigerant English-40Outer Torque If you use a pipe longer than 5 mEnglish-41 Please fill in with indelible ink the factory refrigerant charge of the product 1975Performing the gas leak tests English-42Outdoor unit installed on the wall by rack Fixing the indoor unit in placeFixing the outdoor unit in place English-43Final Check and Trial Operation English-44How to connect your extended power cables English-45Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withTechnical Specifications English-46English-47 Questions or COMMENTS? 0211Air Conditioner