The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

Mode

Indoor temperature

Outdoor temperature

Indoor humidity

Remark

 

 

 

 

 

Cooling

16˚C~32˚C

16˚C~52˚C

Relative humidity 80% or less

AR✴✴JV✴✴

 

 

-10˚C~52˚C

AR✴✴JS✴✴

 

 

 

 

 

 

 

 

Heating

27˚C or less

-15˚C~24˚C

-

AR✴✴JS✴✴

 

 

 

 

 

Dry

18˚C ~ 32˚C

-10˚C~52˚C

-

AR✴✴JV✴✴

AR✴✴JS✴✴

 

 

 

 

If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.

If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of specified capacity according to the using conditions(AR✴✴JS✴✴ model).

Maintaining your air conditioner

Internal protections via the unit control system

This internal protection operates if an internal fault occurs in the air conditioner.

Type

Description

 

 

Against cold air

The internal fan will be off to against cold air when the heat pump is heating.

 

 

De-ice cycle

The internal fan will be off to against cold air when the heat pump is heating.

 

 

Anti-protection of

The compressor will be off to protect internal battery when the air conditioner operates

internal battery

in Cool mode.

 

 

Protect compressor

The air conditioner does not start operating immediately to protect the compressor of

the outdoor unit after it has been started.

 

 

 

• If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may

have deposited at low temperatures.

The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.

ENGLISH

English-9

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 9

2014/9/26 16:38:36

Image 9
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningChecking before use Operation rangesEnglish-9 Checking the name of the parts Main partsEnglish-10 Checking the remote controller Remote controller buttonsEnglish-11 Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-14 Using the Turbo function Adjusting the air flow directionVertical air flow Horizontal air flowMode Press the button on the remote controllerEnglish-16 Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode English-17From the moment you have set the timer Using the Smart Saver functionEnglish-18 If the air conditioner is on If the air conditioner is offUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on Cool/Heat modeCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterEnglish-21 Dry the Air filter in a ventilated areaBio filter English-22Bio filter sky-blue Deodorizing filter English-23Deodorizing filter black English-24 Maintaining the air conditionerAir conditioner TroubleshootingDoes not come out English-25Press the Power button or disconnect the power plug Check if you press the Set/Cancel button on the remoteMode for 1~2 hours. We do not use smelly components Check the Drains have been cleared Regular MaintenanceEnglish-27 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-29 When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-30  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-31Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-34 Smooth the cut edges English-35Torque Cut off the remaining foam insulationCutting or extending the pipe Evacuating the indoor unitEnglish-36 Unscrew the caps at the end of each pipeCorrect Inclined English-37Cracked Wall Indoor unit Drain hose Drain hose must notEnglish-38 Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightEnglish-39 Evacuating the connected pipesEnglish-40 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mPlease fill in with indelible ink English-41 the factory refrigerant charge of the product 1975English-42 Performing the gas leak testsFixing the indoor unit in place Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-43English-44 Final Check and Trial OperationEnglish-45 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner