Samsung AR30JVFUCWKNMG manual General information, English-27

Page 27

INSTALLATION PARTS

Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (2004/108/EC) of the European Union.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

ENGLISH

English-27

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 27

2014/9/26 16:38:50

Image 27
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningChecking before use Operation rangesEnglish-9 Checking the name of the parts Main partsEnglish-10 Checking the remote controller Remote controller buttonsEnglish-11 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-14 Horizontal air flow Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Time Up or Time Down button to set the time Press the button on the remote controllerMode English-16English-17 Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer English-18Cool/Heat mode Using the Auto Clean functionUsing the Quiet function When the air conditioner is turned onOpening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter English-21Bio filter English-22Bio filter sky-blue Deodorizing filter English-23Deodorizing filter black English-24 Maintaining the air conditionerEnglish-25 TroubleshootingAir conditioner Does not come outCheck the Drains have been cleared Regular Maintenance Check if you press the Set/Cancel button on the remotePress the Power button or disconnect the power plug Mode for 1~2 hours. We do not use smelly componentsEnglish-27 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-29  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-30English-31 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-34 Cut off the remaining foam insulation English-35Smooth the cut edges TorqueUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-36Wall Indoor unit Drain hose Drain hose must not English-37Correct Inclined CrackedHose tight Drain hose installationEnglish-38 Two hoses are firmly connected, there is no water leakageEnglish-39 Evacuating the connected pipesIf you use a pipe longer than 5 m Adding RefrigerantEnglish-40 Outer Torque1975 English-41Please fill in with indelible ink  the factory refrigerant charge of the productEnglish-42 Performing the gas leak testsEnglish-43 Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeEnglish-44 Final Check and Trial OperationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-45 Apply heat to the contraction tube to contract itEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner