Samsung AR30JVFUCWKNMG manual Safety precautions, English-3

Page 3

USING PARTS

Safety precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.

Important safety symbols and precautions:

WARNING

Hazards or unsafe practices that may result in severe

personal injury or death.

 

CAUTION

Hazards or unsafe practices that may result in minor

personal injury or property damage.

 

Follow directions.

 

Cut-off the power supply.

Do NOT attempt.

 

Do NOT disassemble.

Make sure the machine is grounded to prevent electric shock.

ENGLISH

FOR INSTALLATION

WARNING

Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line.

Extending the power line may result in electric shock or fire.

Do not use an electric transformer. It may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void warranty on the installed product.

Install a Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner)and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock, fire, explosion, problems with the product.

English-3

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 3

2014/9/26 16:38:36

Image 3
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningChecking before use Operation rangesEnglish-9 Checking the name of the parts Main partsEnglish-10 Checking the remote controller Remote controller buttonsEnglish-11 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-14 Horizontal air flow Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Time Up or Time Down button to set the time Press the button on the remote controllerMode English-16English-17 Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer English-18Cool/Heat mode Using the Auto Clean functionUsing the Quiet function When the air conditioner is turned onOpening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter English-21Bio filter English-22Bio filter sky-blue Deodorizing filter English-23Deodorizing filter black English-24 Maintaining the air conditionerEnglish-25 TroubleshootingAir conditioner Does not come outCheck the Drains have been cleared Regular Maintenance Check if you press the Set/Cancel button on the remotePress the Power button or disconnect the power plug Mode for 1~2 hours. We do not use smelly componentsEnglish-27 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-29  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-30English-31 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-34 Cut off the remaining foam insulation English-35Smooth the cut edges TorqueUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-36Wall Indoor unit Drain hose Drain hose must not English-37Correct Inclined CrackedHose tight Drain hose installationEnglish-38 Two hoses are firmly connected, there is no water leakageEnglish-39 Evacuating the connected pipesIf you use a pipe longer than 5 m Adding RefrigerantEnglish-40 Outer Torque1975 English-41Please fill in with indelible ink  the factory refrigerant charge of the productEnglish-42 Performing the gas leak testsEnglish-43 Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeEnglish-44 Final Check and Trial OperationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-45 Apply heat to the contraction tube to contract itEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner