Adjusting the air flow direction

Air flow can be directed to your desired position.

Vertical air flow

Air flow blades move up and down.

Press the Air swingbutton on the remote controller.

Air swing indicator will be on and air flow blades move up and down continuously to circulate the air.

Press the Air swing button on the remote controller again, to keep the air flow direction in a constant position.

ENGLISH

Horizontal air flow

Make sure one of the blade pin lever that stick out of the air flow blades are not broken.

Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer.

• Be extremely careful with your fingers while adjusting the Horizontal air flow direction.

There is a potential risk of personal injury when the unit is

mishandled.

Blade pin lever

Using the Turbo function

Turbo function will be helpful to cool your room quickly and effectively.

Press the Turbo button on the remote controller during Cool mode.

Turbo indicator appears on the remote controller display and the air conditioner operates in Turbo function for 30 minutes.

Cancel Press the Turbo button once again.

• Turbo function is only available in Cool mode.

• If you press the Mode button while the Turbo function is on, it will cancel the function.

• Temperature/Fan speed cannot be adjusted while using this function.

English-15

MAX4 AR30JV&JS_IB&IM_DB68-04541A_EN.indd 15

2014/9/26 16:38:42

Image 15
Contents MAX4 AR30JV&JSIB&IMDB68-04541AEN.indd 2014/9/26 Contents English-3 Safety precautionsEnglish-4 For Power SupplyEnglish-5 For UsingEnglish-6 English-7 Do not place objects or devices under the indoor unitEnglish-8 For CleaningChecking before use Operation rangesEnglish-9 Checking the name of the parts Main partsEnglish-10 Checking the remote controller Remote controller buttonsEnglish-11 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-14 Horizontal air flow Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Time Up or Time Down button to set the time Press the button on the remote controllerMode English-16English-17 Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer English-18Cool/Heat mode Using the Auto Clean functionUsing the Quiet function When the air conditioner is turned onOpening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter English-21Bio filter English-22Bio filter sky-blue Deodorizing filter English-23Deodorizing filter black English-24 Maintaining the air conditionerEnglish-25 TroubleshootingAir conditioner Does not come outCheck the Drains have been cleared Regular Maintenance Check if you press the Set/Cancel button on the remotePress the Power button or disconnect the power plug Mode for 1~2 hours. We do not use smelly componentsEnglish-27 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-29  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-30English-31 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-34 Cut off the remaining foam insulation English-35Smooth the cut edges TorqueUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-36Wall Indoor unit Drain hose Drain hose must not English-37Correct Inclined CrackedHose tight Drain hose installationEnglish-38 Two hoses are firmly connected, there is no water leakageEnglish-39 Evacuating the connected pipesIf you use a pipe longer than 5 m Adding RefrigerantEnglish-40 Outer Torque1975 English-41Please fill in with indelible ink  the factory refrigerant charge of the productEnglish-42 Performing the gas leak testsEnglish-43 Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeEnglish-44 Final Check and Trial OperationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-45 Apply heat to the contraction tube to contract itEnglish-46 Technical SpecificationsEnglish-47 0211 Questions or COMMENTS?Air Conditioner