Samsung AQ24UGAN, AQ09UGDN manual Contents

Page 2

In this manual, you may find model names written in simplified forms as indicated in following table.

Model

Included Models

Remark

Names

 

 

 

 

 

AQE

AQ09E, AQ12E,

 

AQ18E, AQ24E

Grouping

AQR

AQ09R

was done by

AQU

AQ09U, AQ12U,

series.

 

 

AQ18U, AQ24U

 

09

AQ09E, AQ09R,

 

AQ09U

Grouping

12

AQ12E, AQ12U

was done by

18

AQ18E, AQ18U

capacity.

24

AQ24E, AQ24U

 

Simplfied model names were used in pages 5, 8, 9, 10, 11, 18, 20.

E-2

Vivaldi_IM_30271A_E_11.07.09.indd 2

Contents

SAFETY PRECAUTIONS

3

PREPARING FOR INSTALLATION

 Choosing the Installation Location

5

 Accessories

8

INSTALLING THE AIR CONDITIONER

 Fixing the Installation Plate

. . . 9

  Connecting the Assembly Cable

. . 10

  Installing and Connecting the Assembly Pipe of the Indoor Unit

. . . 12

 Purging the Indoor Unit

. . 13

  Cutting or Extending the Pipe

. . . 14

  Installing and Connecting the Drain Hose of the Indoor Unit . . . .

. . 15

  Changing Direction of the Drain Hose

. . 16

  Installing and Connecting the Drain Hose of the Outdoor Unit . .

. . . 17

COMPLETING THE INSTALLATION

  Purging the Connected Pipes

18

 Performing the Gas Leak Tests

20

  Fixing the Indoor Unit in Place

21

  Fixing the Outdoor Unit in Place

21

 Final Check and Trial Operation

22

 Providing Information for User

23

  Pump Down Procedure (When removing the product)

23

2009-11-7 13:55:40

Image 2
Contents Vivaldi IM30271AE11.07.09.indd 2009-11-7 Contents Safety Precautions EnglishMinor personal injury or property Choosing the Installation Location Model Figure Description Top view Side viewWhen installing more than 1 outdoor unit Accessories in the Outdoor Unit Case AccessoriesAccessories in the Indoor Unit Case Following accessories are supplied with the air conditionerFixing the Installation Plate Direction of pipeConnecting the Assembly Cable Model Power cable Interconnection Type GLIndoor unit Outdoor unitOuter Diameter Torque kgfcm DO not Wall UP the Pipe ConnectionPurging the Indoor Unit Cutting or Extending the Pipe Depth a Flaring Size BInstalling and Connecting the Drain Hose of the Indoor Unit Drain hose installation Direction of the drained water Change the direction only when it is necessaryChanging Direction of the Drain Hose Installing and Connecting the Drain Hose of the Outdoor Unit You should purge the air in the indoor unit and in the pipe Purging the Connected PipesWith a Global Warming Potential GWP = Reduction of cooling capacity and malfunctionGWP value Add refrigerant charge according to table below If you use a pipe Then 1975Leak Test with Nitrogen before opening valves Performing the Gas Leak TestsTo check for gas leaks on Leak Test with R410A after opening valvesFixing the Indoor Unit in Place Fixing the Outdoor Unit in PlaceFinal Check and Trial Operation Storage in a handy and safe place Pump Down Procedure When removing the productProviding Information for User Vivaldi IM30271AE11.07.09.indd 2009-11-7 Installation Manual Cooling and Heating