PREPARING FOR INSTALLATION

Choosing the Installation Location

Indoor Unit

Where airflow is not blocked

Where cool air can be distributed throughout the room

Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram

Wall that prevents vibration and is strong enough to hold the product weight

Out of the direct sunlight

1m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

As far away as possible from the fluorescent and incandescent lights (so that the remote control can be operated well)

A place where the air filter can be replaced easily

CAUTION

Outdoor Unit

Where it is not exposed to strong wind

Well ventilated and dustless places

Out of the direct sunlight and rain

Where neighbors are not annoyed by operation sound or hot air

Solid wall or support that prevents vibration and is strong enough to hold the product weight

Where there is no risk of flammable gas leakage

When installing the unit at a high place be sure to fix the unit legs

3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

Install the unit horizontally

Place where drained water does not become any problem.

Place with no plants (especially climbing plants) and where small animal can not access.

ENGLISH

Avoid the following places to prevent malfunction of the unit

- Where there is machine oil

- Salty environment such as seaside areas

- Where sulfide gas exists

- Other special atmosphere areas

Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.

125mm or more

Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. Refer to page 19 for further details.

300mm or more

125mm or more

You can select the direction of draining (left or right).

600mm minimum

300mm minimum

600mm minimum

CAUTION:

'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration)

'L ' meters maximum total pipe length

300mm minimum

'H ' meters maximum total pipe length

Model

L

H

09

15

7

12

15

7

18

15

7

24

20

8

Make at least one round:

It will reduce noise and vibration

The appearance of the unit may be different from the diagram

E-5

depending on the model.

 

Vivaldi_IM_30271A_E_11.07.09.indd 5

2009-11-7 13:55:43

Image 5
Contents Vivaldi IM30271AE11.07.09.indd 2009-11-7 Contents English Safety PrecautionsMinor personal injury or property Model Choosing the Installation LocationTop view Side view  Figure DescriptionWhen installing more than 1 outdoor unit Accessories in the Indoor Unit Case AccessoriesAccessories in the Outdoor Unit Case Following accessories are supplied with the air conditionerDirection of pipe Fixing the Installation PlateModel Power cable Interconnection Type GL Connecting the Assembly CableOutdoor unit Indoor unitDO not Wall UP the Pipe Connection Outer Diameter Torque kgfcmPurging the Indoor Unit Depth a Flaring Size B Cutting or Extending the PipeDrain hose installation Installing and Connecting the Drain Hose of the Indoor Unit Direction of the drained water Change the direction only when it is necessaryChanging Direction of the Drain Hose Installing and Connecting the Drain Hose of the Outdoor Unit With a Global Warming Potential GWP = Purging the Connected PipesYou should purge the air in the indoor unit and in the pipe Reduction of cooling capacity and malfunction If you use a pipe Then Add refrigerant charge according to table belowGWP value 1975To check for gas leaks on Performing the Gas Leak TestsLeak Test with Nitrogen before opening valves Leak Test with R410A after opening valvesFixing the Outdoor Unit in Place Fixing the Indoor Unit in PlaceFinal Check and Trial Operation Storage in a handy and safe place Pump Down Procedure When removing the productProviding Information for User Vivaldi IM30271AE11.07.09.indd 2009-11-7 Cooling and Heating Installation Manual