Samsung AQ09UGDN, AQ24UGAN manual Fixing the Indoor Unit in Place, Fixing the Outdoor Unit in Place

Page 21

Fixing the Indoor Unit in Place

Perform the following work on the area where gas leak test was done priorly.

COMPLETING THE INSTALLATION

ENGLISH

After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate.

1To avoid condensation problems, wrap foam insulation (as shown in the figure A) on a part without insulation on the end of the pipes.

2Wind the pipe, assembly cable and drain hose with vinyl tape.

3Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

CAUTION Make sure pipe does not move when you install the indoor unit on an installation plate.

5Wrap the rest of the pipe with vinyl tape.

6Attach the pipe to the wall using clamps (optional).

<Figure A>

Insulation

Pipes

Installation plate

Vinyl tape

Connecting

pipes

 

Connecting wires

Drain hose

Fixing the Outdoor Unit in Place

Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

1Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

2Fix the outdoor unit in level to an appropriate support using anchor bolts.

3If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

Note Secure the rubber leg to prevent the generation of noise and vibration.

OUTDOOR UNIT INSTALLED ON THE WALL BY RACK

-Ensure the wall will be able to suspend the weight of rack and outdoor unit;

-Install the rack close to the column as much as possible;

-Install proper grommet in order to reduce noise and residual vibration trans- ferred by outdoor unit towards wall.

'X' mm

 

'Y' mm

 

 

Rubber leg

 

Model

X

Y

AQ09R/UA

457

254

AQ09E/AQ12

538

290

AQ18

543

319

AQ24

660

340

 

Designed to cut off

 

residual vibration from

 

outdoor unit to rack. (not

 

supplied with product)

Soft rubber designed to cut off vibration from rack to wall.

(not supplied with product)

E-21

Vivaldi_IM_30271A_E_11.07.09.indd 21

2009-11-7 13:57:15

Image 21
Contents Vivaldi IM30271AE11.07.09.indd 2009-11-7 Contents English Safety PrecautionsMinor personal injury or property Model Choosing the Installation LocationTop view Side view  Figure DescriptionWhen installing more than 1 outdoor unit Accessories in the Indoor Unit Case AccessoriesAccessories in the Outdoor Unit Case Following accessories are supplied with the air conditionerDirection of pipe Fixing the Installation PlateModel Power cable Interconnection Type GL Connecting the Assembly CableOutdoor unit Indoor unitDO not Wall UP the Pipe Connection Outer Diameter Torque kgfcmPurging the Indoor Unit Depth a Flaring Size B Cutting or Extending the PipeDrain hose installation Installing and Connecting the Drain Hose of the Indoor UnitChange the direction only when it is necessary Changing Direction of the Drain Hose Direction of the drained water Installing and Connecting the Drain Hose of the Outdoor Unit With a Global Warming Potential GWP = Purging the Connected PipesYou should purge the air in the indoor unit and in the pipe Reduction of cooling capacity and malfunction If you use a pipe Then Add refrigerant charge according to table belowGWP value 1975To check for gas leaks on Performing the Gas Leak TestsLeak Test with Nitrogen before opening valves Leak Test with R410A after opening valvesFixing the Outdoor Unit in Place Fixing the Indoor Unit in PlaceFinal Check and Trial Operation Pump Down Procedure When removing the product Providing Information for UserStorage in a handy and safe place Vivaldi IM30271AE11.07.09.indd 2009-11-7 Cooling and Heating Installation Manual