Samsung AQ09UGDN, AQ24UGAN manual Fixing the Installation Plate, Direction of pipe

Page 9

Fixing the Installation Plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

Right (A)

Left (B)

Underside_right (C)

Rear_right or left (D)

1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

CAUTION Make sure to drill only one hole after choosing the direction of the pipe.

2Fix the indoor unit.

If you fix the indoor unit on a wall

(1)Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Note If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.

Plastic Anchor

INSTALLING THE AIR CONDTIONER

ENGLISH

Direction of pipe

A B

DD C

(Unit : mm) AQ12, AQ09E/U

Pipe hole (Ø65mm)

27

27

12068

(Unit : mm) AQ18

Pipe hole (Ø65mm)

27

27

19068

(Unit : mm) AQ24

Pipe hole (Ø65mm)

<20mm

Wall

34

34

14068

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

CAUTION Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

CAUTION

Fix the installation plate without incling to one side.

WARNING

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not strong enough to withstand the product weight, the unit could fall and cause injury.

(Unit : mm) AQ09R

Pipe hole (Ø65mm)

27

27

140160

E-9

Vivaldi_IM_30271A_E_11.07.09.indd 9

2009-11-7 13:56:17

Image 9
Contents Vivaldi IM30271AE11.07.09.indd 2009-11-7 Contents English Safety PrecautionsMinor personal injury or property Model Choosing the Installation LocationTop view Side view  Figure DescriptionWhen installing more than 1 outdoor unit Accessories in the Indoor Unit Case AccessoriesAccessories in the Outdoor Unit Case Following accessories are supplied with the air conditionerDirection of pipe Fixing the Installation PlateModel Power cable Interconnection Type GL Connecting the Assembly CableOutdoor unit Indoor unitDO not Wall UP the Pipe Connection Outer Diameter Torque kgfcmPurging the Indoor Unit Depth a Flaring Size B Cutting or Extending the PipeDrain hose installation Installing and Connecting the Drain Hose of the Indoor UnitChange the direction only when it is necessary Changing Direction of the Drain Hose Direction of the drained water Installing and Connecting the Drain Hose of the Outdoor Unit With a Global Warming Potential GWP = Purging the Connected PipesYou should purge the air in the indoor unit and in the pipe Reduction of cooling capacity and malfunction If you use a pipe Then Add refrigerant charge according to table belowGWP value 1975To check for gas leaks on Performing the Gas Leak TestsLeak Test with Nitrogen before opening valves Leak Test with R410A after opening valvesFixing the Outdoor Unit in Place Fixing the Indoor Unit in PlaceFinal Check and Trial Operation Pump Down Procedure When removing the product Providing Information for UserStorage in a handy and safe place Vivaldi IM30271AE11.07.09.indd 2009-11-7 Cooling and Heating Installation Manual