Heatiator CR36D, CL36D owner manual Framing & Clearances, Select Fireplace Location

Page 18

6 Framing & Clearances

A. Select Fireplace Location

 

As room divider

 

23 in.

 

45 in.

48 in. Min.

18 in. minimum from

front opening to sidewall

 

 

45 in.

 

23 in.

48 in. Min.

Note: 18 in. minimum from front opening to sidewall.

Note: 1/2 in. min. distance from fireplace to combustible materials.

Note: In addition to these framing dimensions, also reference the following sections:

Clearances (Section 6.B.)

Mantel Projections (Section 11.E.)

Fireplace Dimensions (Section 13.A.)

Figure 6.1 Fireplace Locations (Framing dimensions shown)

18

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

Image 18
Contents Wood Burning Fireplace Hot screen/mesh and glass doors will cause burnsFire Risk Listing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Non-Combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Grate Seasoned WoodStarting a Fire FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOutside Air optional Optional ComponentsWood Fuel Hardwood vs SoftwoodMaintenance and Service Chimney Inspection/CleaningDisposal of Ashes Inspect Grate Glass CleaningCheck Firebox Refractory Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDesign and Installation Considerations DraftNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Mantel Leg or Wall ProjectionsFrame the Fireplace RequiredPosition the Fireplace Installation of FireplaceThings to Consider Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Install Ceiling FirestopsAssemble Chimney Sections Install Attic Insulation Shield Mm overlapComplete Installation Install FlashingCut out Hole in Roof Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST375 Square Termination Cap Shrouds Radiation ShieldField Constructed Shrouds Mailbox Style Shroud radiation shield required Finishing Hearth Extension= 1/k x inches of thickness Finishing Material In. Micore or equivilent insulationCombustible Mantel Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Wood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsChimney Components Catalog #14-1/2 10-7/8 276 mm Service Parts CL36DParts Contact Information
Related manuals
Manual 48 pages 44.09 Kb