Inside

 

Diameter

 

8 in. (203 mm)

Effective

Outside

Height

Diameter

4-3/4 in.

10-1/2 in.

(121 mm)

(267 mm)

SL315/SL330 Offset/Return

Assembled

Diameter: 14 1/2 in./368 mm

Height: 24 in./610 mm

AS8 Straight Attic Insulation Shield

10-1/2 in.

(267 mm)

2 in. (51 mm)

JB877 Chimney Joint Band

10-1/2 in. (267 mm)

CB876 Chimney Joint Band

7 3/4 in.

26 in.

CT-3A

A

B

 

14-1/2 in.

 

 

(368 mm)

 

Ceiling Firestop

 

 

 

 

 

 

 

Catalog #

A

 

B

FS338

0-deg.

14-1/2 in.

 

368 mm

FS339

15-deg.

18-3/8 in.

 

467 mm

 

 

 

 

 

FS340

30-deg.

23 in.

 

584 mm

12in.

(305 mm)

27-3/8 in.

24-5/8 in.

(695 mm)

(625 mm)

RF370 Roof Flashing

12in.

(305 mm)

31 in.

24-5/8 in.

(625 mm)

(787 mm)

 

RF371 Roof Flashing

 

TR-TVK

TR Top Vent Kit

44

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

Image 44
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Outside Air optionalVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Hardwood vs SoftwoodDisposal of Ashes Maintenance and ServiceChimney Inspection/Cleaning Glass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Mantel Leg or Wall ProjectionsFrame the Fireplace RequiredInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleAssemble Chimney Sections Install Chimney Air KitInstall Ceiling Firestops Install Attic Insulation Shield Mm overlapCut out Hole in Roof Complete InstallationInstall Flashing Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension Finishing Material In. Micore or equivilent insulationCombustible Mantel Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsChimney Components Catalog #14-1/2 10-7/8 276 mm Service Parts CL36DParts Contact Information