H. Glass Doors

Glass doors are optional.

Refer to Figure 2.2 for how to properly use them.

WARNING! Risk of Fire! Install ONLY doors ap- proved by Hearth & Home Technologies, Inc.

WARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace opening.

CORRECT

CORRECT

INCORRECT

Figure 2.2 Operating Positions of Bi-fold Doors

I. Outside Air (optional)

The outside air kit supplies some combustion air for your fireplace. It may help reduce the effects of negative air pressure. (See Section 5.D.)

Refer to Figure 2.1 for location of control

Close the inlet to prevent cold drafts when the fireplace is not being used.

CAUTION! Risk of Burns! The outside air control handle is HOT when fireplace is in operation. Adjust BEFORE lighting fire.

J. Vented Gas Log Sets & Gas Log Lighters

Optional

Vented gas logs or gas log lighters can be installed in this fireplace. Follow the instructions provided with the accessory for operation.

WARNING! Risk of Fire or Asphyxiation!

DO NOT install unvented gas logs.

Damper must be locked open.

Gas flame may generate fumes.

K. Optional Components

Other options may be available

Consult your dealer/distributor

WARNING! Risk of Fire! DO NOT install and or use any component not approved by Hearth & Home Tech- nologies Inc.

L. Clear Space

Do not place combustible objects within areas indicated in Figure 2.3.

WARNING! DO NOT place combustible objects in front of the fireplace. High temperatures may ignite clothing, furniture or draperies.

Mantel - avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.

18 in. (45.7 cm)

Clear Space

from

Opening of

Fireplace

48 in. (121.9 cm)

Clear Space

Front of Fireplace

Figure 2.3 Clear Space

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

9

Image 9
Contents Wood Burning Fireplace Hot screen/mesh and glass doors will cause burnsFire Risk Listing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenOutside Air optional Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelMaintenance and Service Chimney Inspection/CleaningDisposal of Ashes Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesMantel Leg or Wall Projections Sidewalls/SurroundsRequired Frame the FireplaceThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsInstall Chimney Air Kit Install Ceiling FirestopsAssemble Chimney Sections Mm overlap Install Attic Insulation ShieldComplete Installation Install FlashingCut out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST375 Square Termination Cap Shrouds Radiation ShieldField Constructed Shrouds Mailbox Style Shroud radiation shield required Finishing Hearth Extension= 1/k x inches of thickness In. Micore or equivilent insulation Finishing MaterialMantel Combustible Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsCatalog # Chimney Components14-1/2 10-7/8 276 mm CL36D Service PartsParts Contact Information