Heatiator CR36D, CL36D owner manual deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min

Page 40

F. Sidewalls/Surrounds

• Adjacent combustible sidewalls must be located

• Combustible or non-combustible mantel legs, surrounds

a minimum of 18 in. (457 mm) from the fireplace

and stub walls may be constructed per Figure 11.5.

opening.

 

48 in. Min.

36-5/8 in.

16 3/4 in. Minimum

48 in. Min.

20 in.

50 deg

BRICK

FRONT 4 in.

34 in.

14-1/2 in.

 

 

39 deg

 

18 in. Min.

20 in.

50 deg

16 3/4 in. Minimum

14-1/2 in.

39 deg

18 in. Min.

Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening)

40

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

Image 40
Contents Hot screen/mesh and glass doors will cause burns Wood Burning FireplaceFire Risk Grate Listing Label Information/LocationNumber Installer Guide Table of ContentsUser Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Seasoned Wood Starting a FireGrate FirescreenGlass Doors Outside Air optionalVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Hardwood vs SoftwoodChimney Inspection/Cleaning Maintenance and ServiceDisposal of Ashes Glass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDraft Design and Installation ConsiderationsNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Mantel Leg or Wall ProjectionsFrame the Fireplace RequiredInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Ceiling Firestops Install Chimney Air KitAssemble Chimney Sections Install Attic Insulation Shield Mm overlapInstall Flashing Complete InstallationCut out Hole in Roof Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Chase Top Install Fireplace & ChimneyInstall Termination Cap ST375 Square Termination Cap Radiation Shield ShroudsField Constructed Shrouds Mailbox Style Shroud radiation shield required Hearth Extension Finishing= 1/k x inches of thickness Finishing Material In. Micore or equivilent insulationCombustible Mantel Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsChimney Components Catalog #14-1/2 10-7/8 276 mm Service Parts CL36DParts Contact Information
Related manuals
Manual 48 pages 44.09 Kb