F. Install Attic Insulation Shield

WARNING! Risk of Fire! You MUST install an attic insu- lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

DO NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

DO NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.6 - 8.8.

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space (refer to Figure 8.6).

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

WARNING! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

 

Bend remaining tabs

 

to rest against pipe to

Bend inward

prevent insulation

90°

from falling in.

 

Insert three

 

screws

3 in. (76 mm) overlap

Figure 8.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

10-1/2 in.

(267 mm)

Figure 8.7 Install Attic Insulation Shield (firestop above ceiling)

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

10-1/2 in.

Pipe

Ceiling Firestop

(267 mm)

 

 

Figure 8.8 Install Attic Insulation Shield (firestop below ceiling)

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

29

Image 29
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Starting a Fire Seasoned WoodGrate FirescreenOutside Air optional Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelDisposal of Ashes Maintenance and ServiceChimney Inspection/Cleaning Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesMantel Leg or Wall Projections Sidewalls/SurroundsRequired Frame the FireplaceThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstall Ceiling Firestops Mm overlap Install Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension In. Micore or equivilent insulation Finishing MaterialMantel Combustible Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsCatalog # Chimney Components14-1/2 10-7/8 276 mm CL36D Service PartsParts Contact Information