C. Sidewalls/Surrounds

Adjacent combustible sidewalls must be located a minimum of 18 in. (305 mm) from the front fireplace opening.

Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area, Figure 6.3.

 

 

 

 

BRICK

 

 

 

 

FRONT

48 in. Min.

 

48 in. Min.

 

4 in.

 

 

 

36-5/8 in.

20 in.

 

34 in.

14-1/2 in.

 

 

 

 

 

 

50 deg

 

39 deg

16 3/4 in.

 

 

 

Minimum

 

 

 

 

 

 

 

 

18 in. Min.

20 in.

 

 

 

14-1/2 in.

 

 

 

 

39 deg

 

50 deg

 

 

 

16 3/4 in.

 

18 in. Min.

 

 

Minimum

 

 

 

Figure 6.3 Mantel Leg or Wall Projections

 

 

 

 

20

Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09

Image 20
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Limited Warranty Heatilator CL36D, CR36D 12538 Rev V 05/09 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Outside Air optionalVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Hardwood vs SoftwoodDisposal of Ashes Maintenance and ServiceChimney Inspection/Cleaning Glass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Mantel Leg or Wall ProjectionsFrame the Fireplace RequiredInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleAssemble Chimney Sections Install Chimney Air KitInstall Ceiling Firestops Install Attic Insulation Shield Mm overlapCut out Hole in Roof Complete InstallationInstall Flashing Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension Finishing Material In. Micore or equivilent insulationCombustible Mantel Mantel50 deg 16 3/4 in. Minimum 14-1/2 39 deg 18 in. Min Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsChimney Components Catalog #14-1/2 10-7/8 276 mm Service Parts CL36DParts Contact Information
Related manuals
Manual 48 pages 44.09 Kb