Heath Zenith SL-4290 Series warranty Bulb Replacement, Specifications, Ping points

Page 6

Walk through the coverage area noting

where you are when the lights turn on.

Move the sensor head left or right to

change the coverage area.

BULB REPLACEMENT

If lantern has an open bottom, insert bulb through opening and screw into socket.

IMPORTANT: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force the sensor past the stop-

If lantern has a closed bottom, follow the steps below to replace bulb.

1.Place one hand under lower glass assembly and un- screw decorative screws holding lower glass as- sembly to top of fixture.

2.Replace bulb.

3.Reattach lower glass assembly to fixture top us- ing decorative screws.

Decorative Screws

Light

Bulb

Lower Glass

Assembly

ping points.

 

 

°

1

 

0

5

 

5

 

 

 

°

1

 

 

0

 

 

 

Rotating Sensor Head to Change

Coverage Area

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

SPECIFICATIONS

Range

Up to 30 ft. (9.1 m) [varies with

 

 

surrounding temperature].

Sensing Angle

Up to 150°

Electrical Load

Up to 100 Watt Maximum

 

 

Tungsten Incandescent

Sensor Capacity

Up to 360 Watt (3.0 A.)

 

 

 

Maximum Tungsten

 

 

 

Incandescent

Power Requirements

.......... 120 VAC, 60 Hz

Operating Modes

TEST, AUTO, and

 

 

 

MANUAL MODE

Time Delay

 

1, 5, 10 minutes

DualBrite® timer

Off, 3, 6 hrs,

 

 

 

Dusk-to-Dawn

6

598-1277-02

Image 6
Contents DualBrite Motion Sensing Diecast Lantern OperationInstallation Mode Switching SummaryDualBrite Dimmer Control Wiring Two Motion Lights Recommended Grounding MethodOptional Wiring Wiring DiagramTesting Complete InstallationLower ARM Installation OnlyRotating Sensor Head to Change Coverage Area Bulb ReplacementSpecifications Ping pointsTroubleshooting Guide Technical ServiceNo Service Parts Available for this Product Five Year Limited Warranty Farol DualBrite de fundición con detector de movimiento FuncionamientoLuz de Adorno DualBrite InstalacionResumen de las modalidades del Interruptor ADVERTENCIADesconecte la ener- gía en el disyuntorCableado Conexion Alterna Alcance Máximo Angulo de Cobertura Máxima Complete LA InstalacionPrueba Lo menos sensible Lo más sensibleReemplazo DE LA Bombilla EspecificacionesGuia DE Investigacion DE Averias Servicio TécnicoNo hay piezas de servicio disponibles para este producto Garantía Limitada a 5 Años Caractéristiques FonctionnementRésumé du mode de commutation Minuterie DualBriteMDMéthode de mise à la terre recommandée CâblageCâblage Facultatif Modèle 4294 seulement Complétez LinstallationInstallation DU Bras Inférieur EssaisRemplacement DE Lampoule Fiche TechniqueRotation du capteur pour modifier la Zone de couverture Service Technique Guide DE DépannageGarantie Limitée DE 5 ANS