TROUBLESHOOTING
 WARNING: Never attempt to service heater while it is connected to propane/LP supply, operating, or hot. Severe burns can occur.
SYMPTOM | POSSIBLE CAUSE | REMEDY | ||
  | 
  | 
  | 
  | |
Burner fails to light  | 1. Propane/LPsupply valve closed  | 1.  | Open propane/LP supply  | |
  | 
  | on propane/LP cylinder  | 
  | valve slowly  | 
  | 2.  | Blockage in burner/orifice  | 2.  | Clean burner/replace orifice  | 
  | 
  | elbow/hose and regulator as-  | 
  | elbow/hose and regulator as-  | 
  | 
  | sembly  | 
  | sembly  | 
  | 3.  | Piezo ignition system not  | 3.  | Verify ignitor electrode gap is  | 
  | 
  | sparking | 
  | .20". Check wire lead for dam-  | 
  | 
  | 
  | 
  | age. Replace piezo ignitor and/or  | 
  | 
  | 
  | 
  | ignitor electrode as necessary  | 
Burner lights but goes out when  | 1. Not enough   | 1.  | Relight, hold automatic control  | |
automatic control valve button  | 
  | 
  | 
  | valve button in 30 seconds  | 
is released  | 2. Low gas pressure  | 2.  | Check propane/LP cylinder  | |
  | 
  | 
  | 
  | for proper gas supply  | 
  | 3.  | Thermocouple loose or needs  | 3.  | Tighten connection or replace  | 
  | 
  | to be replaced  | 
  | thermocouple  | 
  | 4.  | Automatic control valve needs  | 4.  | Replace automatic control  | 
  | 
  | to be replaced  | 
  | valve assembly  | 
  | 5.  | Thermocouple gap is too  | 5.  | Tip of thermocouple should  | 
  | 
  | great. | 
  | just touch the emitter material.  | 
  | 
  | 
  | 
  | Loosen bracket screws to move  | 
  | 
  | 
  | 
  | thermocouple closer to burner.  | 
  | 
  | 
  | 
  | Be careful not to allow ignitor  | 
  | 
  | 
  | 
  | to touch. Maintain 0.20"  | 
Maximum burn rate is low  | 1. Low gas pressure  | 1.  | Check gas supply; check  | |
  | 
  | 
  | 
  | regulator output  | 
  | 2.  | Low fuel supply  | 2.  | Consult propane/LP gas supplier  | 
  | 3.  | Restriction in burner/orifice  | 3.  | Clean burner/replace orifice  | 
  | 
  | elbow/hose and regulator as-  | 
  | elbow/hose and regulator as-  | 
  | 
  | sembly  | 
  | sembly  | 
Rating  | SPECIFICATIONS | 
  | |
High  | 35,000 Btu/Hr (39.927 Kj/Hr)  | 
Low  | 22,000 Btu/Hr (23.211 Kj/Hr)  | 
Fuel  | Propane Vapor Only  | 
Fuel Consumption  | 
  | 
Gallons (Liters)/Hour  | Min .24 (.91), Max .38 (1.44)  | 
Pounds (kg)/Hour  | Min 1.02 (.46), Max 1.62 (.73)  | 
Supply Pressure (To Regulator)  | 
  | 
Maximum  | 200 psi (1,379 Kpa)  | 
Minimum, for input adjustment  | 20 psi (137,9 Kpa)  | 
Manifold Pressure psi (Kpa)  | 
  | 
High  | 1.8 psi (12,41 kPa)  | 
Low  | 1.9 psi (13,10 kPa)  | 
Ignitor Gap  | 0.120"  | 
Minimum Temperature  | |
Size - L x W x H  | 
  | 
Heater  | 17.5 x 15 x 42 inches (.44 x .38 x 1.06 m)  | 
Carton  | 22 x 17.5 x 45 inches (.56 x .44 x 1.14 m)  | 
Weight  | 
  | 
Heater  | 3.2 kg (7 lb)  | 
Carton  | 4.1 kg (9 lb)  | 
www.desatech.com  | 7  |