TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM POSSIBLE CAUSE | REMEDY |
Heater produces unwanted 1. | Heater burning vapors from |
odors | paint, hair spray, glues, etc. |
| See IMPORTANT statement |
| above |
2. | Low fuel supply (propane/LP |
| gas) |
3. | Gas leak. See Warning |
| statement at top of page |
1.Ventilate room. Stop using odor causing products while heater is running
2.Refill supply tank
3.Locate and correct all leaks (see Checking Gas Connec- tions, page 11)
Gas odor even when control 1. | Gas leak. See Warning | 1. | Locate and correct all leaks |
knob is in OFF position | statement at top of page |
| (see Checking Gas Connec- |
2. | Control valve defective |
| tions, page 11) |
2. | Replace control valve |
Gas odor during combustion | 1. | Foreign matter between con- |
|
| trol valve and burner |
| 2. | Gas leak. See Warning |
|
| statement at top of page |
1.Take apart gas tubing and remove foreign matter
2.Locate and correct all leaks (see Checking Gas Connec- tions, page 11)
Moisture/condensation noticed | 1. Not enough combustion/ven- | 1. Refer to Air for Combustion |
on windows | tilation air | and Ventilation requirements |
|
| (page 5) |
TECHNICAL SERVICE
You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Productsʼ Technical Service Department at
You can also visit DESA Heating Productsʼtechni- cal service web site at www.desatech.com.
SERVICE PUBLICATIONS
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA Heating Products.
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burner will have delayed ignition
•heater will not produce specified heat
•propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con- tact your local natural or propane/LP gas supplier.
www.desatech.com | 19 |