Desa SPC20PT, SPC20NT, LSF20NT Specifications, SF30NT SF30PT, LSF30NT, VSF30NT LSF30PT, VSF30PT

Page 20

SPECIFICATIONS

REM20NT, SF20NT, SFG20NT,

REM20PT, SF20PT, SFG20PT,

SPC20NT AND VSFG20NT

SPC20PT AND VSFG20PT

Natural Gas

Propane/LP Gas

10,500/20,000 Btu/Hr (Variable)

10,500/20,000 Btu/Hr (Variable)

Piezo Ignition

Piezo Ignition

• Pressure Regulator Setting - 3" W.C.

• Pressure Regulator Setting - 8" W.C.

• Inlet Gas Pressure* (in. of water)

• Inlet Gas Pressure* (in. of water)

 

Maximum - 10.5" - Minimum - 4"

 

Maximum - 14" - Minimum - 11"

LSF20NT, LSFG20NT, VSF20NT AND

LSF20PT, LSFG20PT, VSF20PT AND

VSFG20NT

VSGF20PT

Natural Gas

Propane/LP Gas

15,000/20,000 Btu/Hr (Variable)

10,500/20,000 Btu/Hr (Variable)

Electronic Ignition

Electronic Ignition

• Pressure Regulator Setting - 3" W.C.

• Pressure Regulator Setting - 8" W.C.

• Inlet Gas Pressure* (in. of water)

• Inlet Gas Pressure* (in. of water)

 

Maximum - 10.5" - Minimum - 4"

 

Maximum - 14" - Minimum - 11"

SF30NT

SF30PT

Natural Gas

Propane/LP Gas

15,500/30,000 Btu/Hr (Variable)

15,500/30,000 Btu/Hr (Variable)

Piezo Ignition

Piezo Ignition

• Pressure Regulator Setting - 3" W.C.

• Pressure Regulator Setting - 8" W.C.

• Inlet Gas Pressure* (in. of water)

• Inlet Gas Pressure* (in. of water)

 

Maximum - 10.5" - Minimum - 4"

 

Maximum - 14" - Minimum - 11"

LSF30NT, VSF30NT

LSF30PT, VSF30PT

Natural Gas

Propane/LP Gas

15,500/30,000 Btu/Hr (Variable)

15,500/30,000 Btu/Hr (Variable)

Electronic Ignition

Electronic Ignition

• Pressure Regulator Setting - 3" W.C.

• Pressure Regulator Setting - 8" W.C.

• Inlet Gas Pressure* (in. of water)

• Inlet Gas Pressure* (in. of water)

 

Maximum - 10.5" - Minimum - 4"

 

Maximum - 14" - Minimum - 11"

* For purposes of input adjustment.

20

www.desatech.com

116307-01B

Image 20
Contents What to do if YOU Smell GAS Residential Models Garage ModelsTable of Contents Safety Information Unpacking Product FeaturesLocal Codes Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Ventilation Air From OutdoorsInstalling Heater to Wall Locating HeaterColdest part of room Attaching to wall stud Attaching to wall anchorConnecting to GAS Supply Marking Screw LocationsPlacing Heater On Mounting Screws Locate hardware packet behind left side door of heaterBe upstream from heater see Figure Protects it from freezing rain or sleet30,000 Btu/Hr Models 1/2 or greater Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingInstalling Refractory and Front Panel Lighting Instructions Turn control knob clockwise to the OFF positionManual Lighting Procedure Inspecting HeaterThermostat Control Operation Pilot Flame PatternCleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetContact local propane/LP gas company TroubleshootingObserved Problem Possible Cause Remedy Goes out when control knob is Control knob not pressed Problem could be caused byAssembly Delayed ignition of burners Manifold pressure is too lowNoise when burner is lit Dirty or partially clogged Clean burner see CleaningWhen heated, vapors from Turn heater off when using Turn off air supplyTechnical Service Service Publications Service HintsWhen Gas Pressure Is Too Low Gas leak. See WarningLSF30NT, VSF30NT LSF30PT, VSF30PT SpecificationsSF30NT SF30PT Parts Central AccessoriesReplacement Parts Illustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyQUÉ Hacer SI Percibe Olor a GAS Modelos Modelos Para CocheraTabla DE Contenido Información DE Seguridad Códigos Locales Identificación DEL ProductoDesempaque Características DEL ProductoAire Para Combustión Ventilación Cómo Procurar LA Ventilación AdecuadaConstrucción inusualmente sellada Espacio confinado y no confinadoAire Para Ventilación Aire del interior de la construcción para ventilaciónInstalación Verifique EL Tipo DE GASArtículos DE Instalación Aire del exterior para ventilaciónEn áreas con mucho viento o Ubicación DEL CalentadorInstalación DEL Calentador EN LA Pared Doble en anclaje de pared como se muestra en la figuraColocación del calentador en los tornillos de montaje Coloque el calentador en los tornillos de montajeConexión AL Suministro DE GAS Ventila apuntando hacia abajoGas natural Revisión DE LAS Conexiones DE GASPruebas de presiones mayores a 1/2 PSI 3.5 kPa Abra la válvula de cierre del equipo consulte la figura Instale el panel anterior y el refractarioInstalación del panel anterior y el refractario Instale un difusor frontal como se muestra en la figuraInstrucciones DE Encendido No intente encender ningún aparatoFuncionamiento DEL Inspección DEL CalentadorInspección DEL Limpieza Y MantenimientoEntrada DE Aire AL Piloto DEL Quemador Como se muestra en la figuraSolución DE Problemas Causa Posible RemedioProblema Observado Causa Posible Remedio Baja presión del gasEl termopar está dañado Presione totalmente la perilla de controlEl problema desaparecerá Cierre el suministro de aireSe enciende o se apaga Silbante cuando el quemadorCuando la presión del gas de entrada sea muy baja Servicio TécnicoConsejos Para Servicio LSF30NT, VSF30NT EspecificacionesSF30NT Central DE Piezas AccesoriosPiezas DE Repuesto Clasificación Ilustrada DE Piezas Lista DE Piezas Información DE Garantía Guarde Esta Garantía