Quadra-Fire 839-1290, 839-1320, 839-1340, 844-4120 owner manual Retro Connector

Page 22

FLEX LINER

FLEX COUPLER

SHEET METAL

SCREWS

Figure 5.27

6 in. (152mm)

DIAMETER OPENING IN MASONRY WALL

RETRO CONNECTOR

 

THREE MASONRY BOLTS

Figure 5.29

(NOT INCLUDED)

 

Step 8.

Secure the top adapter to the flashing. Use three sheet metal screws through the side of the top adapter into the flange on the flashing (Figure 5.28). Twist lock the high wind termination cap on to the top adapter.

HIGH WIND

TERMINATION

CAP

TOP ADAPTER

THREE SHEET

METAL SCREWS

FLASHING

Figure 5.28

Step 10.

Slide wall thimble cover over retro connector and secure with masonry bolts (Figure 5.30). If you have a framed wall in front of the masonry, use wood screws to mount wall thimble cover to framed wall, over retro connector and 10 in. (254mm) square framed opening (Figure 5.25, on page 21). If needed, add a section of direct vent pipe to the retro connector in order to extend through the opening in the wall thimble cover.

RETRO CONNECTOR

WALL THIMBLE COVER

FOUR MASONRY BOLTS (NOT INCLUDED)

Figure 5.30

Step 9.

Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector (Figure 5.29). Mount the retro connector to the masonry wall using masonry bolts. Redrill larger holes on connector as needed. Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall.

Step 11.

The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

 

 

 

 

Page 22

Quadra-Fire · Topaz · 7009-113E

January 3, 2007

Image 22
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Manufactured Date Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances Appliance Location and ClearancesSelecting Appliance Location Design Purposes only4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsVenting Guidelines How to Use the Vent GraphExceptions for Horizontal Installations Vertical Distance from Appliance to 90 ElbowHorizontal Termination Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Type aRear Vent 203mm Direct Vent Pipe Vertical TerminationStep Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCap Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksStanding Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthON/OFF Remove Shipping Materials Appliance SetupTop to Rear Vent Conversion Accessories Leg Leveling SystemBrick Installation Front Installation Fronts shipped attached to faceFor Both Quartet and Solitaire Fronts Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower Installation31 Blower Wiring Diagram For TOP or Rear Vent Installations Damper AdjustmentShutter Adjustment Make adjustmentBefore Lighting Appliance Operating InstructionsControls For Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Vent Components List MiscellaneousTopaz Item # DescriptionRD. Service Parts List cont’d BRNR-TOPAZRV-TPZ-CSB RV-TPZ-CCRRV-TPZ-CLG RV-TPZ-CWLCast Parts Individual Pieces RE. Accessories Warranty Policy This page Intentionally Left Blank Quadra-Fire · Topaz · 7009-113E January 3 This page Intentionally Left Blank Contact Information TopazDealer Telephone