Symptom

Possible Cause

Corrective Action

3.

(Continued)

c. Defective valve.

Turn the valve knob to the ON position. Place the ON/OFF switch in the

 

 

 

ON position. Check the millivolt meter at the thermopile terminals. The

 

 

 

millivolt meter should read greater than 125mV. If the reading is accept-

 

 

 

able, and if the burner does not come on, replace the gas valve.

 

 

d. Plugged burner

Check the burner orifice for stoppage. Remove stoppage.

 

 

orifice.

 

 

 

e. Wall switch or

Follow the corrective action in Symptom and Possible Cause 1.a.

 

 

wires are defective.

Check the switch and wiring. Replace where defective.

4.

Frequent pilot outage

a. Pilot flame may

Clean and adjust the pilot flame for maximum flame impingement on

problem.

be too high or too

thermocouple. Follow lighting instructions carefully.

 

 

low, or blowing

 

 

 

(high), causing safety

 

 

 

pilot to drop out.

 

5.

The pilot and main

a. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while

b. Inner vent pipe

Check for proper vent connection at flue collar and all vent joints.

in operation.

leaking exhaust

 

 

 

gases back into the

 

 

 

system.

 

 

 

c. Horizontal vent

The horizontal vent cap should slope down only enough to prevent any

 

 

improperly pitched.

water from entering the appliance.

 

 

d. Bad thermopile or

Replace if necessary.

 

 

thermocouple.

 

 

 

e. Improper vent cap

Check for proper installation and freedom from debris or blockage.

 

 

installation.

 

6.

Glass soots.

a. Flame impinge-

Adjust the log set so that the flame does not excessively impinge on it.

 

 

ment.

Check that logs are placed according to installation instructions.

 

 

b. Improper shutter

Adjust the air shutter at the base of the burner.

 

 

setting.

 

 

 

c. Debris around

Inspect the opening at the base of the burner. NO MATERIAL SHOULD

 

 

opening at base of

BE PLACED IN THIS OPENING.

 

 

burner.

 

7.

Flame burns blue

a. Insufficient

Ensure that the vent cap is installed properly and free of debris. Ensure

and lifts off burner.

oxygen being sup-

that the vent system joints are tight and have no leaks.

 

 

plied.

Ensure that no debris has been placed at the base of, or in the area of

 

 

 

 

 

 

the air holes in the center of the base pan beneath the burner.

 

 

 

Ensure that the glass is tightened properly on the appliance, particu-

 

 

 

larly on top corners.

January 3, 2007

Quadra-Fire · Topaz · 7009-113E

Page 41

Image 41
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Manufactured Date Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Getting Started Design & Installation ConsiderationsInspect Appliance & Components Tools and Supplies NeededSelecting Appliance Location Appliance Location and ClearancesClearances Design Purposes onlyVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsExceptions for Horizontal Installations How to Use the Vent GraphVenting Guidelines Vertical Distance from Appliance to 90 ElbowType B Rear Installations for Use with Rear Vent Kit Up & Out Installations for Top Vent ConfigurationsHorizontal Termination Type aRear Vent 203mm Step Vertical TerminationDirect Vent Pipe Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCap Retro Connector Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Valve Regulator ReplacementPressure Gas PressuresCheck for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Top to Rear Vent Conversion Appliance SetupRemove Shipping Materials Leg Leveling System AccessoriesFor Both Quartet and Solitaire Fronts Front Installation Fronts shipped attached to faceBrick Installation Qty Description Positioning the LogsMineral Wool Blower Installation Glass Door Assembly Replacement31 Blower Wiring Diagram Shutter Adjustment Damper AdjustmentFor TOP or Rear Vent Installations Make adjustmentControls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramVent Components Diagram Miscellaneous Vent Components ListItem # Description TopazBRNR-TOPAZ RD. Service Parts List cont’dRV-TPZ-CLG RV-TPZ-CCRRV-TPZ-CSB RV-TPZ-CWLCast Parts Individual Pieces RE. Accessories Warranty Policy This page Intentionally Left Blank Quadra-Fire · Topaz · 7009-113E January 3 This page Intentionally Left Blank Dealer Telephone TopazContact Information