7 Electrical Information

A. Recommendation for Wire

See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA

C221.1.

B. Connecting to the Appliance

WARNING

Wire 110v to electrical junction box.

Do NOT wire 110v to the valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt systems.

1.This appliance may be used with a wall switch, wall mounted thermostat and / or a remote control.

2.If using thermostat, use one compatible with a millivolt gas valve system.

3.Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

4.Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

5.Use the following chart for wire sizing.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

8.Ensure the thermostat is mounted level for accurate readings.

9.The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

10.If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

Do not connect this appliance to a thermostat serving any other appliance.

Bedroom installation in Canada requires this appliance to be connected to a thermostat.

WARNING

Shock hazard.

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.

C.Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for operation. A wiring diagram is shown in Figure 7.1 on the next page.

This appliance is equipped with a millivolt control valve.

6.Keep wire lengths as short as possible by removing any excess wire length.

7.Low voltage and 110 VAC voltage cannot be shared within the same wall box.

January 3, 2007

Quadra-Fire · Topaz · 7009-113E

Page 27

Image 27
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Manufactured Date Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools and Supplies Needed Design & Installation ConsiderationsGetting Started Inspect Appliance & ComponentsDesign Purposes only Appliance Location and ClearancesSelecting Appliance Location ClearancesVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsVertical Distance from Appliance to 90 Elbow How to Use the Vent GraphExceptions for Horizontal Installations Venting GuidelinesType a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Horizontal TerminationRear Vent 203mm Vertical Termination Direct Vent PipeStep Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCap Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Propane Natural GAS Valve Regulator ReplacementPressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF Appliance Setup Remove Shipping MaterialsTop to Rear Vent Conversion Leg Leveling System AccessoriesFront Installation Fronts shipped attached to face Brick InstallationFor Both Quartet and Solitaire Fronts Qty Description Positioning the LogsMineral Wool Blower Installation Glass Door Assembly Replacement31 Blower Wiring Diagram Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramVent Components Diagram Miscellaneous Vent Components ListItem # Description TopazBRNR-TOPAZ RD. Service Parts List cont’dRV-TPZ-CWL RV-TPZ-CCRRV-TPZ-CLG RV-TPZ-CSBCast Parts Individual Pieces RE. Accessories Warranty Policy This page Intentionally Left Blank Quadra-Fire · Topaz · 7009-113E January 3 This page Intentionally Left Blank Topaz Contact InformationDealer Telephone