Quadra-Fire 839-1320, 839-1340, 839-1290 Troubleshooting, Symptom Possible Cause Corrective Action

Page 40

10 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

Symptom

Possible Cause

Corrective Action

1. After repeated trig-

a. Defective ignitor.

Check the spark at the electrode and pilot. If no spark and electrode

gering of the piezo

 

wire is properly connected, replace the ignitor.

button, the spark ignitor

 

 

b. Defective pilot or

Using a match, light the pilot. If the pilot lights, turn off the pilot and

will not light the pilot.

misaligned electrode

trigger the piezo button again. If the pilot lights, an improper gas/air

 

 

(spark at electrode).

mixture caused the bad lighting and a longer purge period is recom-

 

 

mended. If the pilot will not light, ensure the gap at the electrode and

 

 

pilot is one-eighth (1/8) inch to have a strong spark. If the gas is OK,

 

 

replace the pilot.

 

c. No gas or low gas

Check the remote shut-off valve from the appliance. Usually, there is

 

pressure.

a valve near the gas main. There can be more that one (1) valve from

 

 

the appliance and the main.

 

d. No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

2. The pilot will not stay

a. Defective thermo-

Check that the pilot flame impinges on the thermocouple. Clean and /or

lit after carefully follow-

couple.

adjust the pilot for maximum flame impingement.

ing the lighting instruc-

 

 

tions.

 

Ensure that the thermocouple connection at the gas valve is fully

 

 

inserted and tight (hand tighten plus 1/4 turn).

 

 

Disconnect the thermocouple from the valve, place one millivolt lead

 

 

wire on the tip of the thermocouple and the other meter wire on the

 

 

thermocouple copper lead. Start the pilot and hold the valve knob in. If

 

 

the millivolt reading is less than 15mV, replace the thermocouple.

 

b. Defective valve.

If the thermocouple is producing more than 15 millivolts, replace faulty

 

 

valve.

3. The pilot is burning,

a. ON/OFF switch or

Check the ON/OFF switch and wires for proper connections. Place the

there is no gas to the

wires defective.

jumper wires across the terminals at the switch. If the burner comes on,

burner, the valve knob is

 

replace the defective switch. If the switch is OK, place the jumper wires

in the ON position, and

 

across the switch wires at the gas valve. IF the burner comes on, the

the ON/OFF switch is in

 

wires are faulty or connections are bad.

the ON position.

 

 

b. Thermopile may

If the pilot flame is not close enough physically to the thermopile, adjust

 

not be generating

the pilot flame.

 

sufficient millivoltage.

Be sure the wire connections from the thermopile at the gas valve ter-

 

 

 

 

minals are tight and that the thermopile is fully inserted into the pilot

 

 

bracket.

 

 

Check the thermopile with a millivolt meter. Take the reading at TH-

 

 

TP&TP terminals of the gas valve. The meter should read 325 millivolts

 

 

minimum, while holding the valve knob depressed in the pilot position,

 

 

with the pilot lit, and the ON/OFF switch in the OFF position. Replace

 

 

the faulty thermopile if the reading is below the specified minimum.

 

 

With the pilot in the ON position, disconnect the thermopile leads from

 

 

the valve. Take a reading at the thermopile leads. The reading should

 

 

be 325 millivolts minimum. Replace the thermopile if the reading is

 

 

below the minimum.

 

 

 

 

Page 40

Quadra-Fire · Topaz · 7009-113E

January 3, 2007

Image 40
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Manufactured Date Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Design & Installation Considerations Getting StartedInspect Appliance & Components Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances Design Purposes only4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Exceptions for Horizontal InstallationsVenting Guidelines Vertical Distance from Appliance to 90 ElbowUp & Out Installations for Top Vent Configurations Type B Rear Installations for Use with Rear Vent KitHorizontal Termination Type aRear Vent 203mm Direct Vent Pipe Vertical TerminationStep Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCap Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Remove Shipping Materials Appliance SetupTop to Rear Vent Conversion Accessories Leg Leveling SystemBrick Installation Front Installation Fronts shipped attached to faceFor Both Quartet and Solitaire Fronts Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower Installation31 Blower Wiring Diagram Damper Adjustment Shutter AdjustmentFor TOP or Rear Vent Installations Make adjustmentBefore Lighting Appliance Operating InstructionsControls For Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Vent Components List MiscellaneousTopaz Item # DescriptionRD. Service Parts List cont’d BRNR-TOPAZRV-TPZ-CCR RV-TPZ-CLGRV-TPZ-CSB RV-TPZ-CWLCast Parts Individual Pieces RE. Accessories Warranty Policy This page Intentionally Left Blank Quadra-Fire · Topaz · 7009-113E January 3 This page Intentionally Left Blank Contact Information TopazDealer Telephone