Quadra-Fire 839-1290, 839-1320, 839-1340 Getting Started, Design & Installation Considerations

Page 6

2 Getting Started

A. Design & Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

When planning an installation, it is necessary to determine the following information before installing:

Where the appliance is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Whether optional accessories - devices such as a blower, thermostat or remote control - are desired.

C. Inspect Appliance & Components

WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

Remove cast door and glass door, and set aside on pro- tective surface. See page 34.

Remove log set and component pack from firebox.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING

Keep appliance dry.

Mold or rust may cause odors.

Water may damage controls.

B.Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available. Note: Not all tools will apply to every installation.

Reciprocating saw

Variable Speed Drill/Driver

Pliers

Wrench Set

Hammer

Framing Square

Phillips Screwdriver

Framing Material

Flat Blade Screwdriver

Hi temp caulking material

Plumb Line

Voltmeter

Level

Gloves

Manometer

Safety Glasses

Tape Measure

Non-corrosive Leak Check Solution

 

or combustible gas detector

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

 

 

 

 

Page 6

Quadra-Fire · Topaz · 7009-113E

January 3, 2007

Image 6
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Manufactured Date Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances Appliance Location and ClearancesSelecting Appliance Location Design Purposes only4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsVenting Guidelines How to Use the Vent GraphExceptions for Horizontal Installations Vertical Distance from Appliance to 90 ElbowHorizontal Termination Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Type aRear Vent 203mm Vertical Termination Direct Vent PipeStep Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCap Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Propane Natural GASGas Pressures PressureGas Connection Check for GAS LeaksStanding Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthON/OFF Appliance Setup Remove Shipping MaterialsTop to Rear Vent Conversion Accessories Leg Leveling SystemFront Installation Fronts shipped attached to face Brick InstallationFor Both Quartet and Solitaire Fronts Positioning the Logs Qty DescriptionMineral Wool Glass Door Assembly Replacement Blower Installation31 Blower Wiring Diagram For TOP or Rear Vent Installations Damper AdjustmentShutter Adjustment Make adjustmentOperating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Vent Components List MiscellaneousTopaz Item # DescriptionRD. Service Parts List cont’d BRNR-TOPAZRV-TPZ-CSB RV-TPZ-CCRRV-TPZ-CLG RV-TPZ-CWLCast Parts Individual Pieces RE. Accessories Warranty Policy This page Intentionally Left Blank Quadra-Fire · Topaz · 7009-113E January 3 This page Intentionally Left Blank Topaz Contact InformationDealer Telephone