Napco Security Technologies GEM-P3200 quick start GEM-RP1CAE2/GEM-K1CA Keypad Easy, Program Menu

Page 11

WI818G 10/05

Page 11

USER AUTHORITY LEVEL

KEYPAD DISPLAY FUNCTION MENU

FUNCTION

LEVEL*

DISPLAY ZN FAULTS

1

DISPLAY ZN BYPASSED

1

DISPLAY ZN DIRECTORY

1

ACTIVATE BELL TEST

1

DISPLAY PHONE #’S

1

DISPLAY SYS TRBL

1

DISPLAY FIRE ALARM

1

DISPLAY FIRE TRBL

1

DISPLAY OP/CL

3

ACTIVATE OVERVIEW

3**

ACTIVATE CHIME

1

ACTIVATE WATCH

2

RESET SYSTEM TRBL

3

RESET SENSOR MSG

3

START EXIT TIME

1

FAULT FIND

***

ACTIVATE LOCATE

***

EZM ZONE FIND

***

ACTIVATE DIALER TEST

3

DISPLAY ALARM LOG

3

DISPLAY TOTAL LOG

3

DISPLAY FIRE LOG

3

DISPLAY OP/CL LOG

3

DISPLAY SYSTEM LOG

3

AUTOARM IN 1-4HRS

2

DISPLAY AUTOARM SCHD

3

ACTIVATE PROGRAM

3**

ACTIVATE DOWNLOAD

3

DISPLY RF XMITTER STAT

1

RELAY CONTROL

1

NOTES:

*Minimum Level required to access function

**Level-3 Code with appropriate user option

***Requires Dealer Code

 

USER OPTIONS

 

 

OPTIONS

EXPLANATION

 

 

Disabled

User Code not active in this area.

 

 

Blocked View

Allows User Code to block another code from being viewed by another user.

 

An unblocked code cannot view a blocked code, but a blocked code can

 

view all codes. The master user code and the dealer program code can view

 

all codes.

User Program

User Program Option is enabled for Keypad 1 only, wherever it is connected

 

(any area). If enabled, Level 3 must also be enabled.

Bypass

Allows User Code to bypass zones.

 

 

Overview

This option, along with Level 3 Authorization, enables selection of

 

OVERVIEW mode at a keypad. This Mode provides a system status display

 

of all areas at a glance.

Arm Only

Prevents User Code from disarming this area.

 

 

Service

A Service Code has restricted arm/disarm rights; if an area is armed with a

 

Service Code, a “5” appears on the GEM-RP1CAe2 keypad and the area can

 

be disarmed with any valid User Code, including a Service Code. If the area

 

is armed with OTHER than a Service Code, it CANNOT be disarmed with a

 

Service Code. This is typically used to allow tradesmen access to premises

 

under control of the owner.

Ambush

There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered

 

immediately prior to (and as part of) the regular User Code and (2) A separate

 

and unique User Code. Disarming with an Ambush Code will cause a silent

 

report to be sent to a central station. Thus, should a user be forced to disarm, he

 

can silently signal an emergency while appearing to be merely disarming the

 

system.

Access

This is normally used to activate a door striker while an area is disarmed. A

 

code with the access option will not function as an arm/disarm code. When

 

the code is entered, the keypad will display “ENTER NOW” and the Brown

 

Wire on the keypad will become Active Low (Ground Potential) for 7

 

seconds.

Related User Options: “Ambush Code” (Address 0495), “Panel Access Code” (Address 0490), “Dealer Security Code” (Address 0500) & “User Area Options” (Address 2455-2502).

GEM-RP1CAE2/GEM-K1CA KEYPAD EASY

Press Uto save each code.

To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program a new User Code as previously described. Press NEXT Pbutton to proceed.

Example: Program a code of “2222” for user 02, with User Option of “User Program”, User “Level 3” and Access Control Option “Keypad No. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for access control option.

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press Uto save. Similarly, to cancel a code, blank out each number of the code and press Uto save to

save.

PROGRAM MENU

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Image 11
Contents System Ready 01/01/06 1200 AM Programming InstructionsNapco Security Group, Inc Important NoteTable of Contents Downloading from a Computer System Programming OptionsIntroduction Easy Menu Driven Program Mode Easy Menu Driven Program ModeAccessing Dealer Program Mode Customizing a Default ProgramGEM-RP1CAE2/GEM-K1CA Keypad Easy Program Menu Exit/Entry2 Zones Enter Zone # Enable Telco Line Test?Enable Burg Out Chirp? Chime 2 Zones Enter Zone #Area Keypads Enter KPs Enable SIA CP-01? Y/NMenu GEM-RP1CAE2/GEM-K1CASee WI for Info GEMRP1CAE2/GEM-K1CA Keypad Easy Program Menu Central Station Account #Enter user code 001 123 E3 K1CA Keypad Easy Program MenuGEM-RP1CAE2/GEM Options Explanation GEM-RP1CAE2/GEM-K1CA Keypad EasyProgram Menu User Authority Level Keypad Display Function MenuUser Code ACM Area Keypad Easy Program MenuEnter user code 001 123456 Enter Proximity Card Users for ACM USE only0 0 0 0 0 0 I T # + C S P0 1 0 0 0 0 0 0 0 0 1 E N R O L L aDealer Code RE Enter Keypad EasyDirect Address Overview Direct Address Program ModeAddress Mode Displays Program ModeZones Address Program Mode2406 DirectNo data yet entered 09000900 AmbushProgramming Conventions Used in this Manual Direct Address Program ModeSystem System Delays & Timeouts Address 2407, 2408DELAYS/TIMEOUTS Left Right CodesKeypad System Codes Address 0490 0495 & 0500 0551 CS Receiver 2 Options Format Options0526 CS Receiver 1 Options CS Receiver 3 OptionsAddress 0527-0546 Digits OptionsCS Telco 1 Subscriber OPENING/CLOSING ID Numbers CS Telco 2 Subscriber Event ID Numbers Backup ReportingCS Subscriber ID Numbers Address 0650 CS Subscriber ID Numbers Telco 1CS Telco 3 Subscriber OPENING/CLOSING ID Numbers ID Numbers Telco 3 & CS Reporting CodesCS Subscriber ID Numbers Address 0790 CS Reporting Codes Address 0859CS Area Reporting Options CS Reporting Codes Address 0870CS Area & System Reporting Options Address 1024 AreasCS Zone Reporting CodesCS Zone Reporting Codes Address 0910 Users CS User Reporting Codes Address 1030CS User Reporting Codes Global System Trouble Reporting Options Address 1082 Global System Trouble Reporting OptionsActivated by Area Area System Trouble Reporting Options Address 1120Area System Trouble Reporting Options System Response Area 1 System EVENT/TROUBLEZ12 Z13 Z14 Z15 Z16 Zone Options / Zones 1 16 Address 1200Zone Options / Zones Z10Z26 Z27 Z28 Z29 Z30 Z31 Zone Options / Zones 17 32 Address 1402Z19 Z20 Z22 Z23See Zone Options on Zone Options / Zones 33 48 Address 1602Zone Options / Zones 1- 48 Address 1200 2419 System Options 2416 System Options Enable Day Zone WatchSystem Options Address 2415 2417 System Options3874 System Options ALARM/TROUBLE Reporting Codes Address 3880System Options Address 2420 2422, 3874, 3905, 3880 2422 System OptionsLeft Data Values System Options Address 3882 -3901, 3903 3905System Options System Options ReservedKeypad Options Address 2425 ACM ACM Timeouts Address 2782ACM Zone Options Address 2740 ACM Global Flags AddressACM Door Area Options ACM Scheduled Free Access Address 4072ACM Scheduled Free Access ACM Door Area Options Address 2784Address Device Type ACM OptionsKeypad Home Area / ACM Door #1 Area HEX Address 2425System Option Emergency Free Access AddressSystem Options Address User Area Options User Area Options Address 2455EZM PGM Terminal Control Group Addr A1 EZM Group Options Address 2555EZM Type Data Option Entries Area Arming Options Address 2650 Area Arming Options & Remote Access LoggingRemote Access Logging Address 3184 System Options Enable KeypadArea Output Disarming AreaTurns OFF Tion. Press Uor Dto save Select the number of receiversExternal Relay Control Cond External Relay ControlRelay Event Options Relay # Area None Relay # Area Timeout Event IDRelay Mapping Data Entries Relay # Left Right Areas Controlling Relay Shutoff on Disarm Right Data EntryArea 1 Keypad Ambush Event ID Codes Data Entries OptionRelay Control Relay Event Alarm Type Options Left Data Timeout EntriesNumber of Relay Board Modules Address Direct Address Program User Program ModeSystem Reset Options Address 4091 MODE--USER Program ModeProgramming User Codes with GEM-K1CA Keypad Accessing User Program ModeUser Program Mode User CodesPress Characters Displayed Hold G Sequence Zone Descriptions GEM-RP1CAE2 / GEM-K1CA KeypadsConfiguring the Keypads Keypad Configuration ModeKeypad Installation Program Control Message New Compat #CS Receiver Telephone Number 1-3 Alphabetical IndexAlphabetical Index Contd Keypad System Codes Address 0490-0495 & 0500-0502 Hour Zone Zone OPTION, 30, 31 Address Number Index Global System Trouble Reporting Options Address Number Index ContdClosing Report only on COND. Closing AUTO-BYP VERI-PHONE Zones Priority Over Alarms ALARM/TROUBLE Reporting Codes WI818G 10/05 Page GEM-P3200 Wiring Diagram