Page 32 | WI818G 10/05 |
ZONE OPTIONS / ZONES 33 - 48 (ADDRESS 1602 -1786)
ZONE OPTIONS / ZONES 33-48
|
|
|
| ZONES 33 | 40 |
|
|
|
|
| ZONES 41 | 48 |
|
| ||||
ZONE OPTIONS | ADDR | Z33 | Z34 | Z35 | Z36 | Z37 | Z38 | Z39 | Z40 | ADDR | Z41 | Z42 | Z43 | Z44 | Z45 | Z46 | Z47 | Z48 |
|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Priority | 1602 |
|
|
|
|
|
|
|
| 1702 |
|
|
|
|
|
|
|
|
Priority with Bypass | 1603 |
|
|
|
|
|
|
|
| 1703 |
|
|
|
|
|
|
|
|
1604 |
|
|
|
|
|
|
|
| 1704 |
|
|
|
|
|
|
|
| |
Selective Bypass | 1605 |
|
|
|
|
|
|
|
| 1705 |
|
|
|
|
|
|
|
|
Keyswitch Arming | 1606 |
|
|
|
|
|
|
|
| 1706 |
|
|
|
|
|
|
|
|
1607 |
|
|
|
|
|
|
|
| 1707 |
|
|
|
|
|
|
|
| |
1608 |
|
|
|
|
|
|
|
| 1708 |
|
|
|
|
|
|
|
| |
Never Arm | 1609 |
|
|
|
|
|
|
|
| 1709 |
|
|
|
|
|
|
|
|
1610 |
|
|
|
|
|
|
|
| 1710 |
|
|
|
|
|
|
|
| |
Burg. Alarm Output | 1611 |
|
|
|
|
|
|
|
| 1711 |
|
|
|
|
|
|
|
|
Pulsed Alarm Output | 1612 |
|
|
|
|
|
|
|
| 1712 |
|
|
|
|
|
|
|
|
Fire Output (Lug E9) | 1613 |
|
|
|
|
|
|
|
| 1713 |
|
|
|
|
|
|
|
|
Reset Relay | 1614 |
|
|
|
|
|
|
|
| 1714 |
|
|
|
|
|
|
|
|
Auxiliary Relay | 1615 |
|
|
|
|
|
|
|
| 1715 |
|
|
|
|
|
|
|
|
Entry/Exit 1 | 1616 |
|
|
|
|
|
|
|
| 1716 |
|
|
|
|
|
|
|
|
Entry/Exit 2 | 1617 |
|
|
|
|
|
|
|
| 1717 |
|
|
|
|
|
|
|
|
Exit/Entry Follower | 1618 |
|
|
|
|
|
|
|
| 1718 |
|
|
|
|
|
|
|
|
Auto Reset | 1619 |
|
|
|
|
|
|
|
| 1719 |
|
|
|
|
|
|
|
|
Swinger Shutdown | 1620 |
|
|
|
|
|
|
|
| 1720 |
|
|
|
|
|
|
|
|
Chime | 1621 |
|
|
|
|
|
|
|
| 1721 |
|
|
|
|
|
|
|
|
Abort Delay | 1622 |
|
|
|
|
|
|
|
| 1722 |
|
|
|
|
|
|
|
|
1623 |
|
|
|
|
|
|
|
| 1723 |
|
|
|
|
|
|
|
| |
Day Zone Open | 1624 |
|
|
|
|
|
|
|
| 1724 |
|
|
|
|
|
|
|
|
Day Zone Short | 1625 |
|
|
|
|
|
|
|
| 1725 |
|
|
|
|
|
|
|
|
Alarm on Day Zone | 1626 |
|
|
|
|
|
|
|
| 1726 |
|
|
|
|
|
|
|
|
RPT Alarm Tel 1 | 1627 |
|
|
|
|
|
|
|
| 1727 |
|
|
|
|
|
|
|
|
RPT Alarm Restore Tel 1 | 1628 |
|
|
|
|
|
|
|
| 1728 |
|
|
|
|
|
|
|
|
RPT Trouble Tel 1 | 1629 |
|
|
|
|
|
|
|
| 1729 |
|
|
|
|
|
|
|
|
RPT Trouble Restore Tel 1 | 1630 |
|
|
|
|
|
|
|
| 1730 |
|
|
|
|
|
|
|
|
RPT Alarm Tel 3 | 1635 |
|
|
|
|
|
|
|
| 1735 |
|
|
|
|
|
|
|
|
RPT Alarm Restore Tel 3 | 1636 |
|
|
|
|
|
|
|
| 1736 |
|
|
|
|
|
|
|
|
RPT Trouble Tel 3 | 1637 |
|
|
|
|
|
|
|
| 1737 |
|
|
|
|
|
|
|
|
RPT Trouble Restore Tel 3 | 1638 |
|
|
|
|
|
|
|
| 1738 |
|
|
|
|
|
|
|
|
No EOL Resistor | 1639 |
|
|
|
|
|
|
|
| 1739 |
|
|
|
|
|
|
|
|
Sensor Watch | 1640 |
|
|
|
|
|
|
|
| 1740 |
|
|
|
|
|
|
|
|
Trouble on Open | 1641 |
|
|
|
|
|
|
|
| 1741 |
|
|
|
|
|
|
|
|
Trouble on Short | 1642 |
|
|
|
|
|
|
|
| 1742 |
|
|
|
|
|
|
|
|
Trouble on Night Open | 1643 |
|
|
|
|
|
|
|
| 1743 |
|
|
|
|
|
|
|
|
Zone Area 1 | 1644 |
|
|
|
|
|
|
|
| 1744 |
|
|
|
|
|
|
|
|
Zone Area 2 | 1645 |
|
|
|
|
|
|
|
| 1745 |
|
|
|
|
|
|
|
|
RESERVED | 1653 |
|
|
|
|
|
|
|
| 1753 |
|
|
|
|
|
|
|
|
Zone ANDing Group 1 | 1654 |
|
|
|
|
|
|
|
| 1754 |
|
|
|
|
|
|
|
|
Zone ANDing Group 2 | 1655 |
|
|
|
|
|
|
|
| 1755 |
|
|
|
|
|
|
|
|
Interior #1 Bypass | 1662 |
|
|
|
|
|
|
|
| 1762 |
|
|
|
|
|
|
|
|
Interior #2 Bypass | 1663 |
|
|
|
|
|
|
|
| 1763 |
|
|
|
|
|
|
|
|
Keypad Sounder on Alarm | 1664 |
|
|
|
|
|
|
|
| 1764 |
|
|
|
|
|
|
|
|
Fire (C) | 1675 |
|
|
|
|
|
|
|
| 1775 |
|
|
|
|
|
|
|
|
Fire Alarm Verification (C) | 1676 |
|
|
|
|
|
|
|
| 1776 |
|
|
|
|
|
|
|
|
Interior (STAY) Bypass | 1684 |
|
|
|
|
|
|
|
| 1784 |
|
|
|
|
|
|
|
|
Chime 2 | 1686 |
|
|
|
|
|
|
|
| 1786 |
|
|
|
|
|
|
|
|
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)). Do not program if "K Series" keypads (with "P" and "Q" buttons) are used in the system.
Disable
In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).
See Zone Options on Page 33.