WI818G 10/05
KEYPAD CONFIGURATION MODE
Page 55
GEMINI
#OF ZONES IN AREA 1 ENTER # ZONES XX
US |
|
|
DSTAT |
| |
ARME | NEXT/YES | |
A123 | E | |
|
| D F |
B 456 | PRIOR/NO | |
AREA |
C7890G
COMPUTERIZED SECURITY SYSTEM
This section will focus on configuring the
KEYPAD INSTALLATION
Two types of keypads may be used with the
CONFIGURING THE KEYPADS
A total of up to 7 keypads may be connected to the panel.
Configuring the GEM-RP1CAe2/GEM-K1CA Keypad
Each
To enter the Keypad Configuration Mode: |
| |
1. | Move jumper JP1 (located in the center of the control panel board) from Pins | NORMAL |
| two). NOTE: See Wiring Diagram on page 68. | |
2. | After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address. | KEYPAD |
3. | Press 11123Rand proceed as follows. (Repeat the following procedure for | CONFIGURE |
all keypads).
Keypad Beep
ON
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed, indicating that the tactile beep, which sounds when any button is pressed, is on.
To turn off the tactile beep, press the Ubutton (the Ubutton will toggle the tac- tile beep on and off). Press Rto continue or press Cto exit.
Entry Sounder
ON
Entry Sounder
To turn off the keypad entry sounder during entry time, press U(the Ubutton will toggle the entry sounder on and off). Press Rto continue or press Cto exit.
Keypad Address
01
Keypad Address
If more than one keypad is installed, each must be assigned a unique keypad address (that is, no two keypads may be numbered alike):
Keypads must be numbered consecutively (missing numbers are not permitted)
Only Keypad No. 1 may be used for programming.
To assign the keypad number, proceed as follows:
1.Enter the assigned keypad number
number will be acknowledged by a short beep; an invalid number will be re- jected by a long beep.
2.Press Rto continue or press Cto exit.
LNAPCO Security Systems |