WI818G 10/05 | Page 5 |
EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM - PRELIMINARY INFORMATION
Only Keypad #1 may be used for both dealer and user programming, however this keypad may be located in any area.
The Master Security Code is printed on the panel’s microprocessor can. Use this code to enter the Dealer Program Mode to program a custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized access to the panel. If you forget your Dealer Security Code, use the Master Security Code to enter programming.
After entering codes or data, press the save Ubutton. Data will not be stored into memory unless it is pressed.
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound. Silence the sounder by pressing the Gbutton to continue, or by pressing the Cbutton to exit.
A panel that has been COLD STARTED (Address Location 4093) performs identically to a new panel.
If a
KEYPAD #1: For ease of programming, it is recommended that a
ACCESSING DEALER PROGRAM MODE
1. Press EEEEEER |
|
|
|
|
| |||
|
|
|
|
| ||||
|
| R | CONTROL | |||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| COMMUNCIATOR | |
| Master Security Code |
|
|
|
|
|
| |
| (on microshield) |
|
|
|
| MASTER SECURITY CODE |
| |
|
|
|
|
|
| # - # - # - # - # - # |
| |
|
|
|
|
|
|
|
|
|
2.Press QUntil “ACTIVATE PROGRAM Y/N” appears on the keypad display.
3.Press PTo Enter Dealer Program Mode.
4.Press CCTo Exit Dealer Program Mode when finished.
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
• Total Number of Zones in Area 1 | • Aux Output Activated on Alarm Zones | • Central Station Receiver 1 Format | |||
• | Total Number of Zones in Area 2 | • | Sensor Watch Zones | • | Enter User Codes |
• | Fire Zones in Area 1 | • | Keypad Sounder on Alarm Zones | • | RF Transmitter Points |
• | • | Auto Bypass | • | Quick Method (Enroll Method) | |
• | Report All Zones to Central | • | Enable no EOLR Zones | • | KeyFob Transmitters (as Arm/Disarm & Control |
• | Exit/Entry Zones in Area 1 | • | Enable Telco Line Fault Test | • | Devices) |
• | Interior Zones in Area 1 | • | Enable Burg Output Chirp on Keyfob | KeyFob Transmitters (as Zone Input Devices) | |
• | 24 Hour Zones in Area 1 | • | Enable SIA | • | Enter Zone Descriptions |
• | Chime Zones in Area 1 | • | Number of Keypads in Area 1 | • | Enter Date |
• | Chime 2 Zones in Area 1 | • | Number of Keypads in Area 2 | • | Enter Time |
• | Exit/Entry2 Zones in Area 1 | • | Central Station Receiver 1 Tel. Number | • | Dealer Code |
• | 50mS Loop Response Zones (Note: 750mS is | • | Central Station Receiver 1 Account Number | • | Exit Dealer Program Mode |
required for Loop Response time in UL installations).
This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been loaded, you may alter it as necessary in the Direct Address Program Mode.
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any means, the number of areas, number of zones, fire zones, entry/exit zones and interior zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the C button to enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the Ubutton and start over.
EASY MENU DRIVEN PROGRAM MODE