Napco Security Technologies GEM-P3200 Chime 2 Zones Enter Zone #, Exit/Entry2 Zones Enter Zone #

Page 7

WI818G 10/05

Chime 2 Zones Enter Zone # °°

(Direct Entry)

Exit/Entry2 Zones Enter Zone # °°

(Direct Entry)

50mS Loop Zones Enter Zone # °°

(Direct Entry)

Aux Output Zones

Enter Zone # ° °

(Direct Entry)

Sensor Watch Zns

Enter Zone # ° °

(Direct Entry)

KP Sndr Alrm Zns

Enter Zone # ° °

(Direct Entry)

Auto Byp REnt Zn

Enter Zone # ° °

(Direct Entry)

E nab le No EOL R

Z one s

Y/N

 

(Press YES or NO)

 

 

Enable Telco

 

Line Test?

Y/N

 

(Press YES or NO)

 

 

Enable Burg Out

 

Chirp?

Y/N

 

 

(Press YES or NO)

Page 7

Chime 2 Zones in Area 1 (New Program Only)

Enter the zone numbers which are to be used as Chime 2 Zones.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

NOTE: A chime time of 2 seconds will be automatically programmed.

Chime 2 zones give a distinct pulsating tone when zone is faulted.

Exit/Entry2 Zones in Area 1 (New Program Only)

Enter the zone numbers of zones to be used as Exit/Entry zones.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and repeat for any additional zone(s); press the NEXT/YES button to proceed.

NOTE: An Entry Delay Time of 30 sec. and an Exit Delay Time of 60 sec. will automatically be programmed.

50 mS Loop Response Zones (New Program Only)

Enter the zone numbers of zones to have a 50mS loop response.

Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed. Note: Only

panel zones 01-08 can be programmed for Quick Loop Response. All other zones can be programmed via their respective EZM's (hardwire). Note: 750mS is required for Loop Response time in UL installations.

Aux Output Activated on Alarm Zones (New Program Only)

Enter the zone numbers of zones to activate the Aux Output upon alarm.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

NOTE: An Aux Output Timeout of 15 minutes will automatically be programmed.

Sensor Watch Zones (New Program Only)

Enter the zone numbers of zones to be Sensor Watch zones.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.

Keypad Sounder On Alarm Zones (New Program Only)

Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

Auto Bypass Re-entry Zones (New Program Only) (Not evaluated by UL)

Enter the zone numbers of zones to be Auto Bypass Re-entry zones.

Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.

Press Uto save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.

Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the system (armed) when the zone is subsequently closed.

Enable No EOLR Zones (New Program Only)

Press YES to program all zones except 24 Hr & fire zones for No End Of Line Resistor. Press NO to continue.

Do not program this feature for UL Installations.

Enable Telco Line Fault Test?

Press YES to enable Telco Line Fault Test.

Press NO to continue. NOTE: If enabled, a Telco Line Fault Test Delay of 60 sec. will automatically be pro- grammed.

Enable Burg Output Chirp on KeyFob?

Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.

Press the PRIOR/NO button to continue.

NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.

GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU

LNAPCO Security Systems

XGEM-P3200 Programming Instructions

Image 7
Contents System Ready 01/01/06 1200 AM Programming InstructionsNapco Security Group, Inc Important NoteTable of Contents Introduction System Programming OptionsDownloading from a Computer Easy Menu Driven Program Mode Easy Menu Driven Program ModeAccessing Dealer Program Mode Customizing a Default ProgramGEM-RP1CAE2/GEM-K1CA Keypad Easy Program Menu Exit/Entry2 Zones Enter Zone # Enable Telco Line Test?Enable Burg Out Chirp? Chime 2 Zones Enter Zone #Area Keypads Enter KPs Enable SIA CP-01? Y/NMenu GEM-RP1CAE2/GEM-K1CASee WI for Info GEMRP1CAE2/GEM-K1CA Keypad Easy Program Menu Central Station Account #GEM-RP1CAE2/GEM K1CA Keypad Easy Program MenuEnter user code 001 123 E3 Options Explanation GEM-RP1CAE2/GEM-K1CA Keypad EasyProgram Menu User Authority Level Keypad Display Function MenuUser Code ACM Area Keypad Easy Program MenuEnter user code 001 123456 Enter Proximity Card Users for ACM USE only0 0 0 0 0 0 I T # + C S P0 1 0 0 0 0 0 0 0 0 1 E N R O L L aDealer Code RE Enter Keypad EasyDirect Address Overview Direct Address Program ModeAddress Mode Displays Program ModeZones Address Program Mode2406 DirectNo data yet entered 09000900 AmbushProgramming Conventions Used in this Manual Direct Address Program ModeDELAYS/TIMEOUTS System Delays & Timeouts Address 2407, 2408System Keypad System Codes Address 0490 0495 & 0500 CodesLeft Right 0551 CS Receiver 2 Options Format Options0526 CS Receiver 1 Options CS Receiver 3 OptionsAddress 0527-0546 Digits OptionsCS Telco 1 Subscriber OPENING/CLOSING ID Numbers CS Telco 2 Subscriber Event ID Numbers Backup ReportingCS Subscriber ID Numbers Address 0650 CS Subscriber ID Numbers Telco 1CS Telco 3 Subscriber OPENING/CLOSING ID Numbers ID Numbers Telco 3 & CS Reporting CodesCS Subscriber ID Numbers Address 0790 CS Reporting Codes Address 0859CS Area Reporting Options CS Reporting Codes Address 0870CS Area & System Reporting Options Address 1024 AreasCS Zone Reporting Codes Address 0910 Reporting CodesCS Zone CS User Reporting Codes CS User Reporting Codes Address 1030Users Global System Trouble Reporting Options Address 1082 Global System Trouble Reporting OptionsActivated by Area Area System Trouble Reporting Options Address 1120Area System Trouble Reporting Options System Response Area 1 System EVENT/TROUBLEZ12 Z13 Z14 Z15 Z16 Zone Options / Zones 1 16 Address 1200Zone Options / Zones Z10Z26 Z27 Z28 Z29 Z30 Z31 Zone Options / Zones 17 32 Address 1402Z19 Z20 Z22 Z23See Zone Options on Zone Options / Zones 33 48 Address 1602Zone Options / Zones 1- 48 Address 1200 2419 System Options 2416 System Options Enable Day Zone WatchSystem Options Address 2415 2417 System Options3874 System Options ALARM/TROUBLE Reporting Codes Address 3880System Options Address 2420 2422, 3874, 3905, 3880 2422 System OptionsLeft Data Values System Options Address 3882 -3901, 3903 3905System Options System Options ReservedKeypad Options Address 2425 ACM ACM Timeouts Address 2782ACM Zone Options Address 2740 ACM Global Flags AddressACM Door Area Options ACM Scheduled Free Access Address 4072ACM Scheduled Free Access ACM Door Area Options Address 2784Address Device Type ACM OptionsKeypad Home Area / ACM Door #1 Area HEX Address 2425System Options Address Emergency Free Access AddressSystem Option User Area Options User Area Options Address 2455EZM Type Data Option Entries EZM Group Options Address 2555EZM PGM Terminal Control Group Addr A1 Area Arming Options Address 2650 Area Arming Options & Remote Access LoggingRemote Access Logging Address 3184 System Options Enable KeypadTurns OFF Disarming AreaArea Output Tion. Press Uor Dto save Select the number of receiversExternal Relay Control Relay Event Options Relay # Area External Relay ControlCond None Relay # Area Timeout Event IDRelay Mapping Data Entries Relay # Left Right Areas Controlling Relay Shutoff on Disarm Right Data EntryArea 1 Keypad Ambush Event ID Codes Data Entries OptionNumber of Relay Board Modules Address Relay Event Alarm Type Options Left Data Timeout EntriesRelay Control Direct Address Program User Program ModeSystem Reset Options Address 4091 MODE--USER Program ModeProgramming User Codes with GEM-K1CA Keypad Accessing User Program ModeUser Program Mode User CodesPress Characters Displayed Hold G Sequence Zone Descriptions GEM-RP1CAE2 / GEM-K1CA KeypadsKeypad Installation Keypad Configuration ModeConfiguring the Keypads Program Control Message New Compat #CS Receiver Telephone Number 1-3 Alphabetical IndexAlphabetical Index Contd Keypad System Codes Address 0490-0495 & 0500-0502 Hour Zone Zone OPTION, 30, 31 Address Number Index Global System Trouble Reporting Options Address Number Index ContdClosing Report only on COND. Closing AUTO-BYP VERI-PHONE Zones Priority Over Alarms ALARM/TROUBLE Reporting Codes WI818G 10/05 Page GEM-P3200 Wiring Diagram