10. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST )
The compressor won't enter operation status for 2 minutes and 20 seconds after the compressor is stopped, even if any operation is given.
11. FOUR-WAY VALVE EXTENSION SELECT
At the time when the air conditioner is switched from the cooling mode to heating mode, the compressor is stopped, and the
12. AUTO RESTART
When the power was interrupted by a power failure, etc. during operation, the operation contents at that time are memorized and when power is recovered, operation is automatically started with the memorized operation contents.
When the power is interrupted and recovered during timer operation, since the timer operation time is shifted by the time the power was interrupted, an alarm is given by blinking (7 sec ON/2 sec OFF) the indoor unit body Timer lamp.
[ Operation contents memorized when the power is interrupted ]
Operation mode Set temperature Set air flow
Timer mode and set time Set air flow Direction Swing
ECONOMY operation
13. MANUAL AUTO OPERATION (Indoor unit body operation)
When the remote control is lost or battery power dissipated, this function will work without the remote control. When MANUAL AUTO button is set more than 3seconds and less than 10seconds, MANUAL AUTO OPERATION will be started as shown in Table14.
To stop operation, press the MANUAL AUTO button for 3seconds.
(Table14 : MANUAL AUTO OPERATION)
| Manual auto operation |
OPERATION MODE | Auto changeover |
FAN CONT. MODE | Auto |
TIMER MODE | Continuous (No timer setting available) |
SETTING TEMP. | 24°C (75°F) |
SETTING LOUVER | Standard |
SWING | OFF |
ECONOMY | OFF |
Press and hold MANUAL AUTO button for 3 ~ 10seconds