Trouble shooting 5 INDOOR UNIT Error Method:
Indoor unit Heat Ex. middle temp. sensor error
Indicate or Display:
Refer to error code table.
Detective Actuators:
Indoor unit Controller PCB Heat Ex. temperature thermistor
Detective details:
When Heat Ex. temperature thermistor open or
Forecast of Cause :
1. Connector connection failure 2.Thermistor failure 3. Controller PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or
OK |
|
|
|
|
|
|
|
Check Point 2 : Remove connector and check Thermistor resistance value | |||||||
Thermistor Characteristics (Approx. value) |
|
|
|
| |||
Temperature |
| 0°C | 5°C | 10°C | 20°C | ||
| (14°F) | (23°F) | (32°F) | (41°F) | (50°F) | (68°F) | |
|
| ||||||
Resistance Value (k | ) | 295.1 | 223.3 | 170.7 | 131.4 | 102.1 | 62.9 |
Temperature |
| 30°C | 40°C | 50°C | 60°C | 63°C |
|
| (86°F) | (104°F) | (122°F) | (140°F) | (144°F) |
| |
|
|
| |||||
Resistance Value (k | ) | 39.78 | 25.8 | 17.11 | 11.6 | 10.36 |
|
If Thermistor is either open or shorted, replace it and reset the power. |
| ||||||
OK |
|
|
|
|
|
|
|
Check Point 3 : Check voltage of Controller PCB (DC5.0V)
Make sure circuit diagram of indoor unit and check terminal voltage at Thermistor (DC5.0V)
THERMISTOR |
|
|
|
(PIPE) |
|
|
|
BLACK | 1 | 1 |
|
BLACK | 2 | 2 | CN4 |
BLACK | 3 | 3 |
|
BLACK | 4 | 4 |
|
THERMISTOR |
|
|
|
(ROOM TEMP.) |
|
|
|
If the voltage does not appear, replace Controller PCB.