4. AUTO CHANGEOVER OPERATION
When the air conditioner is set to the AUTO mode by remote control, operation starts in the optimum mode from among the Heating, Cooling, Dry and Monitoring modes.
During operation, the optimum mode is automatically switched in accordance with temperature changes. The temperature can be set between 18°C (64°F) and 30°C (88°F) in 1°C (2°F) steps.
(Fig. 3 : Operation flow chart in Auto changeover)
| START |
|
|
|
| Room temp. |
| YES |
|
| >Ts+2°C (4°F) ? |
|
|
|
| NO | TS : Setting temperature |
| |
NO | Room temp. |
|
|
|
| <Ts- 2°C(4°F) ? |
|
|
|
| YES |
|
|
|
| HEATING OPERATION |
| COOLING OPERATION |
|
YES | Thermostat remains |
| Thermostat remains | YES |
| in OFF state for 6 minutes or | in OFF state for 6 minutes or |
| |
| longer? |
| longer? |
|
| NO |
| NO |
|
YES | System stops |
| System stops | YES |
or operation command other than | or operation command other than | |||
| auto changeover operation? |
| auto changeover operation? |
|
| NO |
| NO |
|