Bryant 340MAV Checklist-Installation, Load Calculation, Combustion AIR Vent Piping

Page 46

CHECKLIST—INSTALLATION

 

LOAD CALCULATION

____________

Heating Load (Btuh)

____________

Cooling Load (Btuh)

____________

Furnace Model Selection

COMBUSTION AIR VENT PIPING

 

Termination Location

________

Roof or Sidewall

________

Termination Kit-2 Pipe or Concentric

________

Combustion-Air Pipe Length

________

Combustion-Air Elbow Quantity

________

Vent Pipe Length

________

Vent Pipe Elbow Quantity

________

Pipe Diameter Determined from Sizing Table

________

Pipe Sloped To Furnace

 

Pipe Insulation

________

Over Ceilings

________

Low-Ambient Exposed Pipes

 

Condensate Drain

________

Unit Level or Pitched Forward

________

Internal Tubing Connections Free of Kinks

and Traps

 

________

External Drain Connection Leak Tight and

Sloped

 

________

Condensate Trap Primed before Start-Up

________

Heat Tape Installed if Required

 

CHECKLIST—START-UP

________

Gas Input Rate (Set Within 2 percent of

Rating Plate)

 

________

Temperature Rise Adjusted

 

Thermostat Anticipator

________

Anticipator Setting Adjusted or

________

Cycle Rate (3 Cycles per Hr) Selected

 

Safety Controls Check Operation

________

Primary Limit

________

Pressure Switch

—46—

Image 46
Contents Electrostatic Discharge ESD Precautions Safety ConsiderationsMultipoise Orientations Dimensions Unit SizeVI. GAS Piping and GAS Pipe Pressure Testing SafetyII. General Installation Codes and StandardsElectrostatic Discharge ESD Precautions VII. Electrical ConnectionsGeneral IntroductionApplications II. Upflow ApplicationsCondensate Trap Location Alternate Upflow Orientation Pressure Switch TubingCondensate Trap Tubing Factory-Shipped Orientation Condensate Trap Tubing Alternate Upflow OrientationCondensate Trap Location III. Downflow ApplicationsCondensate Trap Tubing Horizontal Left Tube Configuration Construct a Working Platform IV. Horizontal Left SUPPLY-AIR Discharge ApplicationsHorizontal Right SUPPLY-AIR Discharge Applications Attic Location and Working Platform Location Furnace Location for Proper Condensate Drainage II. Furnace Location Relative to Cooling EquipmentIII. Installation in Horizontal Applications II. Installation in Upflow or Downflow ApplicationsInstallation Leveling Legs if Desired III. Hazardous LocationsFurnace Plenum Opening Floor Opening Casing Opening DimensionsWidth Duct Flanges II. Ductwork Acoustical TreatmentFilter Arrangement III. Supply AIR ConnectionsIV. Return AIR Connections Filter InformationMaximum Capacity of Pipe VI. Bottom Closure PanelVII. GAS Piping Casings onlyFire or Explosion Hazard Electrical ConnectionsWiring III AccessoriesPCB Removal of Existing Furnaces from Common Vent Systems Electrical DataDirect Venting II. COMBUSTION-AIR and Vent PipingControl Center COMBUSTION-AIR and Vent Pipe Termination Clearances Clearance FTExample Combustion-Air and Vent Pipe DiameterCombustion-Air and Vent Pipe Attachment COMBUSTION-AIR Intake Housing Plug Fitting Short Vent 5 to 8 Ft SystemMaximum Allowable Pipe Length FT Altitude FT6001 to 7000‡ Air Intake Housing Plug Fitting Drain Extended Exposed Sidewall Pipes Vent Extension PipeTwo-Pipe Termination Kit Concentric Vent/Air Termination Kit IV. Multiventing and Vent TerminationsRoof Termination Preferred Sidewall Termination of 12 in. or Less II. Application Condensate Drain GeneralIII. Condensate Drain Protection III. Continuous Blower Mode Heating ModeII. Cooling Mode IV. Heat Pump ModeComponent Test START-UP Procedures GeneralIV. Adjustments II. Prime Condensate Trap with WaterInducer Housing Drain Cap BTU/CU FT Orifice Manifold 625 650 Only 7001 675 725 8000 775 750 15% 825 2001to 725 750 Only 4001 775 800 825 5000 875 850 900 925 United States Example 100,000 Btuh Input Furnace Installed AT 4300 FTAltitude Derate Multiplier CanadaGAS Rate CU FT/HR Blower OFF Delay Setup PositionCheck Safety Controls Speed SelectorChecklist II. Check Pressure SwitchCheck Primary Limit Control Load Calculation CHECKLIST-INSTALLATIONCHECKLIST-START-UP Combustion AIR Vent Piping
Related manuals
Manual 12 pages 2.16 Kb Manual 44 pages 12.97 Kb

340MAV specifications

The Bryant 340MAV is a standout model in the Bryant lineup, designed to provide exceptional comfort, efficiency, and performance for residential heating and cooling needs. This unit offers a perfect blend of innovative technology and user-friendly features, making it an ideal choice for homeowners seeking reliability and quality.

One of the defining characteristics of the Bryant 340MAV is its impressive efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of up to 18, this model ensures that homeowners can enjoy effective cooling during the summer months while minimizing energy consumption. Similarly, the heating efficiency is notable, with a high AFUE (Annual Fuel Utilization Efficiency) rating. This makes the 340MAV an environmentally friendly option that also promotes cost savings on energy bills.

The 340MAV incorporates advanced technologies that enhance its performance. One such technology is the variable-speed compressor, which allows the system to adjust its output based on the demands of the home. This means that the unit operates more quietly and reduces energy usage by matching the cooling or heating output required. Additionally, the two-stage heating capability provides more consistent temperatures and improved comfort throughout the space.

Operating noise is a crucial factor in residential HVAC systems, and the Bryant 340MAV is designed with this in mind. Engineered for quiet operation, the unit features a sound-dampening design, including an insulated cabinet and a specially designed compressor that minimizes noise levels. Homeowners can enjoy a comfortable indoor climate without the disruptive racket often associated with traditional systems.

Furthermore, the Bryant 340MAV is equipped with a durable all-aluminum coil, which improves heat transfer efficiency while also being resistant to corrosion. This characteristic contributes to the longevity of the unit, ensuring that it can withstand various environmental factors without compromising performance.

Another key feature is the advanced control options that the Bryant 340MAV offers. Integration with smart thermostats allows homeowners to monitor and adjust their HVAC system remotely, ensuring optimal comfort at all times. Additionally, the system is compatible with Bryant's Perfect Airâ„¢ filtration system, enhancing indoor air quality by reducing pollutants and allergens.

In summary, the Bryant 340MAV is a high-efficiency heating and cooling solution that brings together cutting-edge technology, quiet operation, and user-friendly features. With its focus on comfort and energy savings, it stands out as a prime choice for homeowners looking to invest in a reliable HVAC system.