Bryant 340MAV instruction manual 725 750 Only 4001 775 800 825 5000 875 850 900 925

Page 42

 

 

TABLE 10—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

(Continued)

 

 

 

 

 

 

FOR USE WITH 140 SIZE FURNACES ONLY

 

 

 

 

 

 

 

(TABULATED DATA BASED ON 23,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

725

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.8

 

 

 

750

42

 

3.7

42

 

3.8

41

 

3.6

41

 

3.7

41

 

3.8

Only

 

4001

775

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

41

 

3.6

 

 

800

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

 

 

 

 

 

 

 

 

U.S.A.

 

to

825

43

 

3.7

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

 

5000

875

43

 

3.3

43

 

3.4

43

 

3.6

43

 

3.7

43

 

3.8

 

 

 

850

43

 

3.5

43

 

3.6

43

 

3.8

42

 

3.2

42

 

3.3

 

 

 

900

43

 

3.1

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

9%

925

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

950

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

700

41

 

3.5

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.7

 

 

 

725

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.8

 

 

 

750

42

 

3.4

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

 

 

 

775

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.7

Only

 

5001

800

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

 

825

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.2

 

 

 

 

 

 

 

 

U.S.A.

 

to

850

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

 

 

875

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

 

 

 

 

 

 

 

 

 

 

6000

900

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

 

 

 

925

43

 

2.7

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

 

 

 

950

43

 

2.6

43

 

2.7

43

 

2.8

43

 

2.9

43

 

3.0

 

 

11%

975

43

 

2.5

43

 

2.6

43

 

2.6

43

 

2.7

43

 

2.8

 

 

derate

1000

43

 

2.3

43

 

2.4

43

 

2.5

43

 

2.6

43

 

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

650

41

 

3.8

40

 

3.6

40

 

3.7

40

 

3.8

39

 

3.7

 

 

 

675

41

 

3.5

41

 

3.6

41

 

3.7

40

 

3.6

40

 

3.7

Only

 

6001

700

42

 

3.6

42

 

3.7

41

 

3.5

41

 

3.6

41

 

3.7

 

 

725

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

 

 

 

 

 

 

 

 

U.S.A.

 

to

750

43

 

3.8

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

 

7000

800

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

 

 

 

775

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.3

42

 

3.4

 

 

 

825

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

13%

850

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

875

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Orifice numbers shown in BOLD are factory installed.

Percents of derate are based on midpoints of U.S. altitude ranges.

—42—

Image 42
Contents Electrostatic Discharge ESD Precautions Safety ConsiderationsMultipoise Orientations Dimensions Unit SizeVI. GAS Piping and GAS Pipe Pressure Testing SafetyII. General Installation Codes and StandardsElectrostatic Discharge ESD Precautions VII. Electrical ConnectionsGeneral IntroductionApplications II. Upflow ApplicationsCondensate Trap Location Alternate Upflow Orientation Pressure Switch TubingCondensate Trap Tubing Factory-Shipped Orientation Condensate Trap Tubing Alternate Upflow OrientationIII. Downflow Applications Condensate Trap LocationCondensate Trap Tubing Horizontal Left Tube Configuration IV. Horizontal Left SUPPLY-AIR Discharge Applications Construct a Working PlatformHorizontal Right SUPPLY-AIR Discharge Applications Attic Location and Working Platform Location Furnace Location for Proper Condensate Drainage II. Furnace Location Relative to Cooling EquipmentIII. Installation in Horizontal Applications II. Installation in Upflow or Downflow ApplicationsInstallation Leveling Legs if Desired III. Hazardous LocationsOpening Dimensions Furnace Plenum Opening Floor Opening CasingWidth Duct Flanges II. Ductwork Acoustical TreatmentFilter Arrangement III. Supply AIR ConnectionsIV. Return AIR Connections Filter InformationMaximum Capacity of Pipe VI. Bottom Closure PanelVII. GAS Piping Casings onlyFire or Explosion Hazard Electrical ConnectionsWiring III AccessoriesPCB Removal of Existing Furnaces from Common Vent Systems Electrical DataDirect Venting II. COMBUSTION-AIR and Vent PipingControl Center COMBUSTION-AIR and Vent Pipe Termination Clearances Clearance FTCombustion-Air and Vent Pipe Diameter ExampleCombustion-Air and Vent Pipe Attachment COMBUSTION-AIR Intake Housing Plug Fitting Short Vent 5 to 8 Ft SystemMaximum Allowable Pipe Length FT Altitude FT6001 to 7000‡ Air Intake Housing Plug Fitting Drain Vent Extension Pipe Extended Exposed Sidewall PipesTwo-Pipe Termination Kit Concentric Vent/Air Termination Kit IV. Multiventing and Vent TerminationsRoof Termination Preferred Sidewall Termination of 12 in. or Less Condensate Drain General II. ApplicationIII. Condensate Drain Protection III. Continuous Blower Mode Heating ModeII. Cooling Mode IV. Heat Pump ModeComponent Test START-UP Procedures GeneralIV. Adjustments II. Prime Condensate Trap with WaterInducer Housing Drain Cap BTU/CU FT Orifice Manifold 625 650 Only 7001 675 725 8000 775 750 15% 825 2001to 725 750 Only 4001 775 800 825 5000 875 850 900 925 United States Example 100,000 Btuh Input Furnace Installed AT 4300 FTAltitude Derate Multiplier CanadaGAS Rate CU FT/HR Blower OFF Delay Setup PositionCheck Safety Controls Speed SelectorII. Check Pressure Switch ChecklistCheck Primary Limit Control Load Calculation CHECKLIST-INSTALLATIONCHECKLIST-START-UP Combustion AIR Vent Piping