F220 Series Detectors with F220-B6RS Bases

Install the Detector Heads en 21

 

 

CAUTION! When using the locking bar, before installing

!the detector head, open the unlocking port (refer to Figure 4.2, Item 4) by poking through the plastic with a

screwdriver.

4.1.2Mounting Skirt (Figure 4.2, Item 2)

Align the four alignment keys (refer to Figure 2.2, Item 12 on page 6 and to Figure 4.2, Item 5) and press the mounting skirt firmly down onto the mounting base (Figure 4.2, Item 3) to engage the snap locks

.

6

 

 

1

 

 

7

 

 

 

 

 

 

 

 

 

 

8

 

 

2

 

 

5

 

4

 

 

 

 

 

 

 

 

 

 

 

5

 

5

 

 

 

 

 

 

 

 

3

 

5

 

 

 

 

 

 

 

 

 

 

9

1.

 

Detector head (heat

 

the mounting skirt and

 

 

detector shown in exam-

 

four corresponding places

 

 

ple)

 

 

on the base)

2.

 

Mounting skirt

6.

LED

3.

 

Mounting base

7.

Bar on mounting skirt

4.

 

Locking port

8.

T mark on mounting skirt

5.

 

Alignment keys (four

9.

Locking bar in locked position

 

 

places on the bottom of

 

 

Fig. 4.2 Part Orientation for Mounting

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.029.847 -01 2007.02

Image 21
Contents F220 Series Detectors with F220-B6RS Base Required Maintenance and Testing LegalTrademarks Compatible Control Panels General InformationBase Features About F220 Series Detector Heads F220 Series Detectors3 F220 Series Heat Detector Heads 2 F220 Series Detector FeaturesTechnical Specifications General Specifications4 F220 Series Smoke Detector Heads Base Specifications Install the BasesDetector Specifications Electrical SupervisionPage Loop Wiring Specifications Wire the BasesTerminal Connections EOL ResistorsWire Optional Remote Annunciators Wire F220-B6RS Sounder BasesFour-wire Loop Termination NAC Configurations Local Configurations F220-B6RS Local Configuration DIP Switch Settings D275 Wire F220-B6E Power Supervision Base Wire Power Supervision ModulesF220-B6E D275 Wire D275 Power Supervision ModuleInstall the Detector Heads Mount the Detector HeadsOptional Locking Bar LED Keyed. Do not force them onto the mounting bases Detector HeadTest Mode Sensitivity ModeSet Detector Modes Flash Rate and Trouble Indication Set CleanMe FeatureInspect the Installation Test the InstallationActivate an Alarm at Each Detector Reset the Control PanelTest Each Detector Test the Alarm Loop Perform Nfpa 72 Required TestingTest any CO Sensors USA