Linear DUAL 824 manual For All Models

Page 19

PROGRAMMING DIFFERENT SENSOR TYPES (CONT.)

For DXT-61, DXT-21, DXS-21, DXT-41, & DXS-62A single-button remotes, simply press the unit's button.

NOTE: After the Control Panel recognizes the transmitter, single-button remotes must be re-programmed as “panic buttons” or home automation controllers. Refer to Page 28 in the “Customizing the System” section of this manual.

For DXT-23, DXS-23, & DXT-42 multi-button remotes: Learn the transmitter by pressing the left button. The remote will arm the Control Panel with the left button and disarm with the right button. Labels are provided with the DXT-42 for identifying the buttons.

NOTE: After the Control Panel “learns” the transmitter, multi-button remotes can easily be re-programmed to have the left button arm/disarm the Control Panel and the right button activate/ deactivate the Home Automation output. Refer to the “Advanced Programming” section of this manual.

For All Models:

A single “Bing” tone will sound and the sensor status indicator will stay lit when the sensor is programmed into the Control Panel.

A “Buzz” tone will sound if there is already another sensor programmed to that sensor number.

Exit Setup Mode by pressing the key then press OFF for three seconds. Reminder: The system will automatically exit the Setup Mode and return to Off Mode after three minutes of keypad inactivity.

NOTE: To remove sensors from the Control Panel's memory, see Page 26 in the “Customizing the System” section of this manual.

DXT-21

SEND SIGNAL WITH LEFT BUTTON

DXT-42

LEFT = ARM/DISARM

RIGHT = DISARM

BOTH = EMERGENCY

17

Image 19
Contents Supervised Wireless Security Control Panel Linear LLC IntroductionTable of Contents Control Panel Dual 824 Security SystemPanic Buttons Wireless KeypadRemote Controls DOOR/WINDOW SensorsSecurity System Floor Plan Design the InstallationExample System Overview of Keypads Hardwired KeypadThree system supervisory indicators Five system mode indicatorsHardwired Keypad Features Terminals for hardwired loop inputs Control Panel FeaturesExternal Antenna Control Panel InstallationSystem Location Wall MountingHardwired Keypad Installation ARM/DISARM KEY Station Wiring Hardwired Loop WiringTelephone Line Connection External Alarm Siren ConnectionVoice Response Module Automation Output ConnectionBackup Battery Installation Control Panel Power ConnectionCreate the Master User Code Basic Control Panel ProgrammingGong and four beeps will sound Repeat Steps 3-6 to enable all of the hardwired loops used Program the Hardwired LoopsProgram the Wireless Sensors Programming Different Sensor Types For All Models DXS-10 Wireless Keypad Basic Sensor InstallationTest Sensors DXS-31 & DXS-32 DOOR/WINDOW SensorsLabeling the Sensor Locations Customizing the KeypadChime Mode OFF ModeSystem Operating Modes Manual Bypassing of Sensors Home ModeLit sensor status indicators show which sensors are open Home Instant ModeExit Delay For Leaving the Premises Away ModeSensor Operation in Each System Mode Test ModeSensor Function Table System Trouble Indications Control Panel PowerPower indicator normally glows when AC power is on Wireless Sensor LOW BatteriesRemoving Sensors from the System Customizing the SystemAdding Sensors to the System Gong and fi ve Beeps will soundPress HOME, 7, then Away Making a Sensor a 24-HOUR Door ChimePress HOME, 8, then Away Making a Sensor InteriorMaking a Sensor Perform a Different Function Programming Information Sensor Operation in Each System ModeAdvanced Programming Setup ModeControl Panel Programming Options Changing a Sensors Supervision Changing a Sensors Restore RequirementsEntry Delay Time Exit Delay TimeExit Delay Beeps Remote Control & Hardwire Arming LevelRemote Control & Hardwire Disarming Level Entry Delay BeepsAutomatic Restoral of Bypassed Sensors Silent Burglary AlarmsSilent Emergency Alarms Disabling Quick ArmingAutomation Output on During Alarm Automation Output Mode During AlarmRemote Control & Hardwire ARM/DISARM Chirp Automation Output on During and After AlarmAutomation Output Polarity Automation Output During EXIT/ENTRY DelaysRemote Access Password Automation Output While ArmedAdding Additional User Codes Control Panel Master ResetRemoving Additional User Codes General Communicator Options Communicator ProgrammingVoice Response Communicator EnableWay manual, 3 2-way full duplex using this step WAY AudioCall Limiter Dialing DelayDialing Method Call Routing Reporting FormatSecondary Telephone Number Telephone Number Delays and Special CharactersAccount Number Primary Telephone NumberPoint ID Reporting Report Control Panel TroubleReport Force Arming Opening and Closing ReportsSteps #201-206 General Reporting CodesForce Arming Reporting Code System Reporting CodesFire and Emergency buttons and for each Steps #261-266Steps #234-257 By 2 Format Point ID Alarm Report CodesSteps #210-233 By 2 Format Point ID Trouble Report CodesBy 2 Format Point ID Reporting Codes Important Information