Linear DUAL 824 manual Security System Floor Plan, Example System, Design the Installation

Page 6

2.SECURITY SYSTEM FLOOR PLAN

EXAMPLE SYSTEM

The example shows a typical DUAL 824 system.

Any or all of the accessories shown can be used.

A total of 24 sensors can be used with each Control Panel. Each wireless sensor, hardwired loop, and wireless keypad used occupies a sensor location.

DESIGN THE INSTALLATION

1.Draw a floor plan for the installation.

2.Consider the security needs of the premises.

3.Determine which doors and windows are vulnerable to intrusion.

4.Figure which interior areas an intruder might go to if unlawful entrance is gained.

5.Indicate locations for door/window sensors, interior motion detectors, wireless and hardwired keypads, glass break detectors and external siren speakers.

6.Decide on a centralized location for the security Control Panel.

ES

 

 

 

 

MD

GB

S

S

MS

 

 

HK

 

 

 

LIVING

ENTRY

 

 

S

 

 

 

 

 

 

 

 

 

 

 

MS

 

 

 

 

KITCHEN

S BED

 

DINING

 

CO

 

 

 

 

S

 

 

 

MS

 

 

 

HK

 

SD

 

 

BATH

BED

 

S

 

 

 

 

 

 

CP - CONTROL PANEL HK - HARDWIRED KEYPAD

S - DOOR/WINDOW SENSOR WK - WIRELESS KEYPAD MD - MOTION DETECTOR ES - EXTERNAL SIREN

SD - SMOKE DETECTOR

CO - CARBON MONOXIDE DETECTOR GB - GLASS BREAK SENSOR

MS - HARDWIRED MAGNETIC SWITCH

S

S

DEN

CP

 

 

NOTE: IN NEW CONSTRUCTION, NFPA 72 REQUIRES A SMOKE DETECTOR LOCATED INSIDE EACH BEDROOM AS WELL AS A SMOKE DETECTOR ON EACH LEVEL.

WK

S

GARAGE

GB

MD

Example Residential Security System Floor Plan

4

Image 6
Contents Supervised Wireless Security Control Panel Introduction Linear LLCTable of Contents Dual 824 Security System Control PanelDOOR/WINDOW Sensors Wireless KeypadRemote Controls Panic ButtonsDesign the Installation Security System Floor PlanExample System Five system mode indicators Hardwired KeypadThree system supervisory indicators Overview of KeypadsHardwired Keypad Features Control Panel Features Terminals for hardwired loop inputsWall Mounting Control Panel InstallationSystem Location External AntennaHardwired Keypad Installation Hardwired Loop Wiring ARM/DISARM KEY Station WiringExternal Alarm Siren Connection Telephone Line ConnectionAutomation Output Connection Voice Response ModuleControl Panel Power Connection Backup Battery InstallationBasic Control Panel Programming Create the Master User CodeGong and four beeps will sound Program the Hardwired Loops Repeat Steps 3-6 to enable all of the hardwired loops usedProgram the Wireless Sensors Programming Different Sensor Types For All Models Basic Sensor Installation DXS-10 Wireless KeypadDXS-31 & DXS-32 DOOR/WINDOW Sensors Test SensorsCustomizing the Keypad Labeling the Sensor LocationsOFF Mode Chime ModeSystem Operating Modes Home Instant Mode Home ModeLit sensor status indicators show which sensors are open Manual Bypassing of SensorsAway Mode Exit Delay For Leaving the PremisesTest Mode Sensor Operation in Each System ModeSensor Function Table Wireless Sensor LOW Batteries Control Panel PowerPower indicator normally glows when AC power is on System Trouble IndicationsGong and fi ve Beeps will sound Customizing the SystemAdding Sensors to the System Removing Sensors from the SystemMaking a Sensor Interior Making a Sensor a 24-HOUR Door ChimePress HOME, 8, then Away Press HOME, 7, then AwayProgramming Information Sensor Operation in Each System Mode Making a Sensor Perform a Different FunctionSetup Mode Advanced ProgrammingControl Panel Programming Options Exit Delay Time Changing a Sensors Restore RequirementsEntry Delay Time Changing a Sensors SupervisionEntry Delay Beeps Remote Control & Hardwire Arming LevelRemote Control & Hardwire Disarming Level Exit Delay BeepsDisabling Quick Arming Silent Burglary AlarmsSilent Emergency Alarms Automatic Restoral of Bypassed SensorsAutomation Output on During and After Alarm Automation Output Mode During AlarmRemote Control & Hardwire ARM/DISARM Chirp Automation Output on During AlarmAutomation Output While Armed Automation Output During EXIT/ENTRY DelaysRemote Access Password Automation Output PolarityControl Panel Master Reset Adding Additional User CodesRemoving Additional User Codes Communicator Programming General Communicator OptionsWAY Audio Communicator EnableWay manual, 3 2-way full duplex using this step Voice ResponseDialing Delay Call LimiterDialing Method Reporting Format Call RoutingPrimary Telephone Number Telephone Number Delays and Special CharactersAccount Number Secondary Telephone NumberOpening and Closing Reports Report Control Panel TroubleReport Force Arming Point ID ReportingGeneral Reporting Codes Steps #201-206Steps #261-266 System Reporting CodesFire and Emergency buttons and for each Force Arming Reporting CodeBy 2 Format Point ID Trouble Report Codes By 2 Format Point ID Alarm Report CodesSteps #210-233 Steps #234-257By 2 Format Point ID Reporting Codes Important Information