12.CUSTOMIZING THE SYSTEM

Adding additional sensors will increase the protection provided by the system.

All ground-level perimeter openings and accessible upper-story openings need protection.

Motion detectors can protect interior areas and areas where valuables are kept.

ADDING SENSORS TO THE SYSTEM

1.Always start with the system in Test Mode (enter a user code and press TEST).

2.Enter the master user code then press TEST.

A “Gong” and fi ve “Beeps” will sound.

The sensor status indicators will light for each sensor programmed into the Control Panel.

3.Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05).

NOTE: A sensor can be programmed into more than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function.

The sensor status indicator light will fl ash for the sensor number selected.

4.Activate the sensor. (To add a wireless keypad, press the keypad's key.)

A “Bing” tone will sound when the sensor is programmed into the Control Panel and the sensor status indicator will stay lit.

A “Buzz” tone will sound if there is already another sensor programmed to that sensor number.

5.Enter another sensor number, or exit Setup Mode by pressing thekey then press OFF for three seconds.

REMOVING SENSORS FROM THE SYSTEM

If a previously programmed sensor isn't going to be used with the system anymore, or it's a duplicate that has been entered into more than one sensor location, it should be removed from the Control Panel's memory.

1.Start with the system in Test Mode.

2.Enter the master user code then press TEST.

A “Gong” and fi ve “Beeps” will sound.

The sensor status indicators will light for each sensor programmed into the Control Panel.

3.Enter the sensor number (from 01-24) that you want to remove (you must enter two digits, example: 5 = 05).

The sensor status indicator light will fl ash for the sensor number selected.

4.Press TEST.

A “Bing” tone will sound when the sensor has been removed and the sensor status indicator will turn off.

5.Enter another sensor number, or exit Setup Mode by pressing thekey then press OFF for three seconds.

START IN TEST

MASTER

USER

CODE

1 GONG & 5 BEEPS (SETUP MODE)

NEW SENSOR

NUMBER

SENSOR

INDICATOR

FLASHES

ACTIVATE

SENSOR

1 BING AND SENSOR INDICATOR LIGHTS

REPEAT OR EXIT

START IN TEST

MASTER

USER

CODE

1 GONG & 5 BEEPS (SETUP MODE)

NUMBER OF

SENSOR TO

REMOVE

SENSOR

INDICATOR

FLASHES

REMOVES

SENSOR

1 BING & SENSOR INDICATOR

DARK REPEAT OR EXIT

26

Image 28
Contents Supervised Wireless Security Control Panel Introduction Linear LLCTable of Contents Dual 824 Security System Control PanelWireless Keypad Remote ControlsDOOR/WINDOW Sensors Panic ButtonsSecurity System Floor Plan Design the InstallationExample System Hardwired Keypad Three system supervisory indicatorsFive system mode indicators Overview of KeypadsHardwired Keypad Features Control Panel Features Terminals for hardwired loop inputsControl Panel Installation System LocationWall Mounting External AntennaHardwired Keypad Installation Hardwired Loop Wiring ARM/DISARM KEY Station WiringExternal Alarm Siren Connection Telephone Line ConnectionAutomation Output Connection Voice Response ModuleControl Panel Power Connection Backup Battery InstallationCreate the Master User Code Basic Control Panel ProgrammingGong and four beeps will sound Repeat Steps 3-6 to enable all of the hardwired loops used Program the Hardwired LoopsProgram the Wireless Sensors Programming Different Sensor Types For All Models Basic Sensor Installation DXS-10 Wireless KeypadDXS-31 & DXS-32 DOOR/WINDOW Sensors Test SensorsCustomizing the Keypad Labeling the Sensor LocationsChime Mode OFF ModeSystem Operating Modes Home Mode Lit sensor status indicators show which sensors are openHome Instant Mode Manual Bypassing of SensorsAway Mode Exit Delay For Leaving the PremisesSensor Operation in Each System Mode Test ModeSensor Function Table Control Panel Power Power indicator normally glows when AC power is onWireless Sensor LOW Batteries System Trouble IndicationsCustomizing the System Adding Sensors to the SystemGong and fi ve Beeps will sound Removing Sensors from the SystemMaking a Sensor a 24-HOUR Door Chime Press HOME, 8, then AwayMaking a Sensor Interior Press HOME, 7, then AwayProgramming Information Sensor Operation in Each System Mode Making a Sensor Perform a Different FunctionAdvanced Programming Setup ModeControl Panel Programming Options Changing a Sensors Restore Requirements Entry Delay TimeExit Delay Time Changing a Sensors SupervisionRemote Control & Hardwire Arming Level Remote Control & Hardwire Disarming LevelEntry Delay Beeps Exit Delay BeepsSilent Burglary Alarms Silent Emergency AlarmsDisabling Quick Arming Automatic Restoral of Bypassed SensorsAutomation Output Mode During Alarm Remote Control & Hardwire ARM/DISARM ChirpAutomation Output on During and After Alarm Automation Output on During AlarmAutomation Output During EXIT/ENTRY Delays Remote Access PasswordAutomation Output While Armed Automation Output PolarityAdding Additional User Codes Control Panel Master ResetRemoving Additional User Codes Communicator Programming General Communicator OptionsCommunicator Enable Way manual, 3 2-way full duplex using this stepWAY Audio Voice ResponseCall Limiter Dialing DelayDialing Method Reporting Format Call RoutingTelephone Number Delays and Special Characters Account NumberPrimary Telephone Number Secondary Telephone NumberReport Control Panel Trouble Report Force ArmingOpening and Closing Reports Point ID ReportingGeneral Reporting Codes Steps #201-206System Reporting Codes Fire and Emergency buttons and for eachSteps #261-266 Force Arming Reporting CodeBy 2 Format Point ID Alarm Report Codes Steps #210-233By 2 Format Point ID Trouble Report Codes Steps #234-257By 2 Format Point ID Reporting Codes Important Information