9.CUSTOMIZING THE KEYPAD

The system can be customized for the specific installation.

A label sheet with sensor location names is provided with DUAL 824KP keypads.

Labeling the sensors allows quick and easy identification of where a door or window is open, where any alarms have occurred, where a sensor with a low battery is, or where a sensor with trouble is.

LABELING THE SENSOR LOCATIONS

1.Open the keypad's plastic beauty cover to reveal the sensor identification label area.

2.Open one protected door/window to light its sensor status light on the keypad(s).

3.Choose a label that describes the sensor location, or write the location on a blank label, and stick it in the area next to the sensor number.

4.Close the protected opening that you just labeled.

5.Repeat for each protected opening.

6.Stick the WIRELESS KEYPAD label in the sensor number location for the wireless keypad (if used).

7.Close the beauty cover when finished.

PULL TAB TO

OPEN BEAUTY

COVER

OPEN DOOR OR WINDOW TO

LIGHT SENSOR STATUS

INDICATOR ON KEYPAD(S)

USE SENSOR

LABELS SUPPLIED

TO IDENTIFY EACH

SENSOR LOCATION

USE AN INK PEN TO

CUSTOMIZE BLANK

LABELS

APPLY THE PRE-PRINTED SENSOR

LOCATION LABELS TO SUIT THE

INSTALLATION

BLANK LABELS THAT CAN BE FILLED IN

WITH AN INK PEN ARE ALSO PROVIDED

FOR CUSTOM SENSOR IDENTIFICATION

20

Image 22
Contents Supervised Wireless Security Control Panel Introduction Linear LLCTable of Contents Dual 824 Security System Control PanelDOOR/WINDOW Sensors Wireless KeypadRemote Controls Panic ButtonsSecurity System Floor Plan Design the InstallationExample System Five system mode indicators Hardwired KeypadThree system supervisory indicators Overview of KeypadsHardwired Keypad Features Control Panel Features Terminals for hardwired loop inputsWall Mounting Control Panel InstallationSystem Location External AntennaHardwired Keypad Installation Hardwired Loop Wiring ARM/DISARM KEY Station WiringExternal Alarm Siren Connection Telephone Line ConnectionAutomation Output Connection Voice Response ModuleControl Panel Power Connection Backup Battery InstallationCreate the Master User Code Basic Control Panel ProgrammingGong and four beeps will sound Repeat Steps 3-6 to enable all of the hardwired loops used Program the Hardwired LoopsProgram the Wireless Sensors Programming Different Sensor Types For All Models Basic Sensor Installation DXS-10 Wireless KeypadDXS-31 & DXS-32 DOOR/WINDOW Sensors Test SensorsCustomizing the Keypad Labeling the Sensor LocationsChime Mode OFF ModeSystem Operating Modes Home Instant Mode Home ModeLit sensor status indicators show which sensors are open Manual Bypassing of SensorsAway Mode Exit Delay For Leaving the PremisesSensor Operation in Each System Mode Test ModeSensor Function Table Wireless Sensor LOW Batteries Control Panel PowerPower indicator normally glows when AC power is on System Trouble IndicationsGong and fi ve Beeps will sound Customizing the SystemAdding Sensors to the System Removing Sensors from the SystemMaking a Sensor Interior Making a Sensor a 24-HOUR Door ChimePress HOME, 8, then Away Press HOME, 7, then AwayProgramming Information Sensor Operation in Each System Mode Making a Sensor Perform a Different FunctionAdvanced Programming Setup ModeControl Panel Programming Options Exit Delay Time Changing a Sensors Restore RequirementsEntry Delay Time Changing a Sensors SupervisionEntry Delay Beeps Remote Control & Hardwire Arming LevelRemote Control & Hardwire Disarming Level Exit Delay BeepsDisabling Quick Arming Silent Burglary AlarmsSilent Emergency Alarms Automatic Restoral of Bypassed SensorsAutomation Output on During and After Alarm Automation Output Mode During AlarmRemote Control & Hardwire ARM/DISARM Chirp Automation Output on During AlarmAutomation Output While Armed Automation Output During EXIT/ENTRY DelaysRemote Access Password Automation Output PolarityAdding Additional User Codes Control Panel Master ResetRemoving Additional User Codes Communicator Programming General Communicator OptionsWAY Audio Communicator EnableWay manual, 3 2-way full duplex using this step Voice ResponseCall Limiter Dialing DelayDialing Method Reporting Format Call RoutingPrimary Telephone Number Telephone Number Delays and Special CharactersAccount Number Secondary Telephone NumberOpening and Closing Reports Report Control Panel TroubleReport Force Arming Point ID ReportingGeneral Reporting Codes Steps #201-206Steps #261-266 System Reporting CodesFire and Emergency buttons and for each Force Arming Reporting CodeBy 2 Format Point ID Trouble Report Codes By 2 Format Point ID Alarm Report CodesSteps #210-233 Steps #234-257By 2 Format Point ID Reporting Codes Important Information